Hayward hydrorite uvo3 Owner's Manual

Hayward hydrorite uvo3 Owner's Manual

2” residential uv/ozone sanitizing system
Hide thumbs Also See for hydrorite uvo3:

Advertisement

092596 RevA
HydroRite UVO
3
2" Residential UV/Ozone Sanitizing System
Owner's Manual
Contents
Before you Begin.............2
Installation.....................3
Operation.......................7
Maintenance...................7
FAQs.............................10
Troubleshooting............11
Warranty.......................14
Model: HYD-UVO
Hayward Pool Products
620 Division Street, Elizabeth NJ 07207
Phone (908)-355-7995
www.hayward.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Advertisement

Table of Contents
loading

Summary of Contents for Hayward hydrorite uvo3

  • Page 1: Table Of Contents

    2” Residential UV/Ozone Sanitizing System Owner’s Manual Contents Safety Instructions..1 Before you Begin.....2 Installation.....3 Operation.......7 Maintenance....7 FAQs......10 Troubleshooting....11 Replacement Parts..12 Warranty.......14 Model: HYD-UVO Hayward Pool Products 620 Division Street, Elizabeth NJ 07207 Phone (908)-355-7995 www.hayward.com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 2: Safety Instructions

    Prolonged exposure to the eyes can cause serious injury to the eyes, including blindness. DO NOT VIEW UV LAMP WHILE THE DEVICE IS IN OPERATION. SAVE THESE INSTRUCTIONS • USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 3: Before You Begin

    How the Hayward HydroRite Works The Hayward HydroRite contains a high intensity electrically operated Ultraviolet (UV) lamp which is located inside the unit’s wet chamber. The UV lamp emits light at two separate wavelengths within the UV spectrum; 254 nm and 185 nm. The 254 nm wavelength is called the “germicidal” wavelength. This wavelength is capable of inactivating a wide array of microorganisms such as bacteria, viruses, protozoa (e.g.
  • Page 4: Installation

    HydroRite unit and its installation may save a great deal of time (and expense) later. If you have any questions that are unanswered when you have completed the reading of this manual, contact your supplier or Hayward.
  • Page 5 Plumbing the HydroRite System Although not required, Hayward recommends that the HydroRite system be plumbed in a dedicated loop that can be bypassed as shown on page 3. A three-way valve and actuator are supplied for this purpose. If plumbing a bypass, a tee fitting will be required. A bypass will aid in servicing and maintaining the HydroRite.
  • Page 6: Electrical Connections

    The venturi tube is made of a specific material suitable for its purpose. If replacing the attached, insert tube or if a longer tube is needed, call Hayward Technical Support at 908-355-7995. lamp into the sleeve Ballast Cable and UV Lamp DO NOT TOUCH THE UV LAMP WITH YOUR BARE HANDS.
  • Page 7 HydroRite uses a linecord for input power and must be plugged into a 120V 50/60hz GFCI protected outlet. NOTE: Should the electrical power cord of your HydroRite unit become frayed or damaged, unplug it from the power receptacle and contact Hayward. USE OF A FRAYED OR DAMAGED POWER CORD COULD RESULT IN ELECTRICAL SHOCK CAUSING SERIOUS BODILY INJURY, INCLUDING DEATH.
  • Page 8: Operation

    Cleaning the sleeve should return HydroRite to previous performance. Hayward recommends that you remove the lamp and clean the sleeve every 1-3 months depending on the condition of your pool’s water. The sleeve may need more frequent cleaning in areas of the country that have hard water. The quartz sleeve can be manually cleaned or cleaned with an in-line automatic cleaner.
  • Page 9 (see adjacent diagram). Pinching the baffle at those points will flex the surface enough to “unhook” itself from the light engine. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 10 In other instances, the supplier will refer you to Hayward, who can assist you as well. Please read the Limited Warranty in this manual for your HydroRite unit. It explains fully what is and what is not covered under the Limited Warranty and the warranty periods.
  • Page 11: Faqs

    Is the HydroRite System Designed For Salt Water Use? YES, all plastic components are compatible with pools equipped with Hayward Salt Chlorine Generator Systems. Over time, the stainless steel baffle can be affected by a high salt environment but can be easily replaced if necessary.
  • Page 12: Troubleshooting

    Make sure you have not plugged your device into any power source other than that specified on your device’s electrical label. If you have done so in error, the ballast has been damaged and needs to be replaced. Contact your supplier or Hayward for the correct replacement ballast. A replacement ballast is not warranted.
  • Page 13: Replacement Parts

    2" PVC Pipe Connector Socket ECX12T 2" PVC Pipe Connector Threaded TBX122 2" PVC Union Nut BSX1CAP2 2" PVC Port Cap BSX1PLUG2 PVC Vessel Drain Plug SB2KIT Vessel O-Ring Kit GVA-24 Valve Actuator PSV3S2 3-Port Diverter Valve USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 14 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...
  • Page 15: Warranty

    The express limited warranty above constitutes the entire warranty of Hayward Pool Products with respect to its pool products and is in lieu of all other warranties expressed or implied, including warranties of merchantability or fitness for a particular purpose. In no event shall Hayward Pool products be responsible for any consequential, special or incidental damages of any nature.
  • Page 16 Hayward is a registered trademark and HydroRite is a trademark of Hayward Industries, Inc. © 2015 Hayward Industries, Inc. All other trademarks not owned by Hayward are the property of their respective owners. Hayward is not in any way affiliated with or endorsed by those third parties.

Table of Contents