Cleaning Quartz Sleeve & Lamp Sensor (cont.)
Pro Tip: Disconnecting the vessel sensor cable before the lamps will provide more
room to access the lamp connections for removal.
Step 5
Step 6
Disconnect the three Ozone tubes from the
Disconnect the lamp sensor located in the
Ozone manifold (tubes are fixed to lamps).
center of the vessel cap (counterclockwise).
Step 7
Step 8
Remove lamps*, rotating the base connection
*Disconnect lamps from ballast cables,
counter-clockwise and pull lamps straight out.
followed by the interlock sensor.
*IMPORTANT: Always wear included gloves when handling lamps, DO NOT touch the lamps
23
with bare hands.