Calibrating the HydroRite
NOTE: Calibration of the UV lamps SHOULD ONLY be conducted when all three lamps
have been replaced. DO NOT calibrate if servicing the vessel or quartz sleeves only.
Step 1
Step 2
Once new lamps have been installed, plug in
Access the menu by holding the menu button
the controller & make sure lamps are off.
located just above the center of the screen.
Step 3
Step 4
Toggle the display, using the arrows, until
The display should show 'YES', press enter
"CAL" appears & then press enter.
again to accept.
IMPORTANT: Prior to Calibrating the HydrorRite, the water MUST be balanced (including
20
target free chlorine levels between 1-3ppm).