Replacing the Clean Filter

Style Plus uses a clean filter in triple layers of Purafil catalyst, HEPA filter and deodorizing filter in order to
filter the pollutant that may be generated in a FFF type printer.
If excessive pollutants get attached to the clean filter, it not only lowers the performance of the filter but
also may cause a breakdown by interfering the operation of a filter fan.
If excessive pollutants get attached to the clean filter, replace the filter rather than cleaning it.
Even though the replacement cycle of the clean filter may vary by the environment of the use and the
printing habits of a user, it is recommended to replace it in every 6 months under the typical environment.
As for the replacement method, refer to '​
R eplacing the Clean
Filter​ ' above.
Be sure to mount the clean filter in the correct direction.
If the mounting direction is incorrect, the filter performance would be lowered and it may
cause a breakdown of the ventilation fan.
Replacement of a clean filter must take place after confirming that the power is turned off.
During the replacement, be cautious not to let any foreign particle get in.