Exchanging The Eeprom Devices - Cisco 7500 Series Configuration Manual

Cisco systems bridge/router installation and configuration guide
Hide thumbs Also See for 7500 Series:
Table of Contents

Advertisement

Chapter 7
Maintaining Your Cisco 7513, Cisco 7513-MX, and Cisco 7576 Router
If you plan to replace your existing card cage assembly with a new one, you must first perform the
Note
procedure in the
card cage assembly. However, if you simply plan to remove your card cage assembly and then reinstall
it, you do not need this procedure; instead, proceed to the
on page

Exchanging the EEPROM Devices

The following procedure requires you to first exchange the blank EEPROM devices on your new card
cage for the old EEPROM devices from your old card cage, and then place the blank EEPROM devices
on your old card cage for return to Cisco Systems.
Note
You do not need to perform this procedure if you do not plan to install a new card cage assembly;
however, if you do plan to install a new card cage assembly, you must exchange the new electrically
erasable programmable read-only memory (EEPROM) devices on the rear of the new card cage for the
old EEPROM devices on the rear of your old card cage.
The EEPROM devices on your old card cage have MAC addresses programmed into them, which are
necessary for your system to function properly, and these old EEPROM devices are therefore required
for your system to operate properly with a new card cage assembly.
Do not perform these steps if you are upgrading a Cisco 7513 to a Cisco 7576. These instructions apply
Note
only to the replacement of an equivalent model card cage.
To prevent system problems after installation, note that the new EEPROM devices that shipped on your
Caution
new card cage are blank and must be replaced if you plan to replace your card cage with a new one.
For this procedure, you will need a small piece of masking or cellophane tape to mark the new EEPROM
devices as blank. (The old card cage is assumed to have already been removed from your Cisco 7513,
Cisco 7513-MX, or Cisco 7576 using the procedure in the
on page
Use the following procedure to exchange the EEPROM devices:
Attach an ESD preventive wrist strap between you and an unpainted surface of the Cisco 7513, Cisco
Step 1
7513-MX, or Cisco 7576 chassis.
Locate the blank EEPROM devices, located on the rear of the new card cage near the chassis interface
Step 2
board(s). (See
Remove the blank EEPROM devices from the new card cage, place a piece of tape on them to mark them
Step 3
as blank EEPROM devices, and set them aside.
Locate the old EEPROM devices, located on the rear of your old card cage. (See
Step 4
7513 and Cisco 7513-MX, and
OL-5008-03 B0
"Exchanging the EEPROM Devices" section on page 7-7
7-9.
7-5.)
Figure 7-5
for the Cisco 7513 and Cisco 7513-MX, and
Figure 7-6
Maintenance Procedures for the Cisco 7513, Cisco 7513-MX, and Cisco 7576
"Installing the Card Cage Assembly" section
"Removing the Card Cage Assembly" section
for the Cisco 7576.)
Cisco 7500 Series Installation and Configuration Guide
before you install your new
Figure 7-6
for the Cisco 7576.)
Figure 7-5
for the Cisco
7-7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

750775137505

Table of Contents