Cisco 7500 Series Configuration Manual page 112

Cisco systems bridge/router installation and configuration guide
Hide thumbs Also See for 7500 Series:
Table of Contents

Advertisement

Environmental Monitoring and Reporting Overview for the Cisco 7500 Series
The current temperature measurements at the three RSP sensors are displayed as inlet, hotpoint, and
exhaust. The shutdown temperature source is the hotpoint sensor, which is located toward the center of
the RSP. System voltage measurements are also displayed, followed by the system current measurements
and power supply wattage calculation.
The current monitor circuits of the 7513 power supply are only accurate at high power levels. They are
Note
there to prevent over-configuration and serve no purpose at low power levels. If the system is not
operating above 70% power, the measurement results are not accurate. Above 70%, the measurements
have the degree of accuracy needed to prevent the insertion of too many line cards into the system.
Following is sample output of the show env all command:
Router# show env all
Environmental Statistics
Environmental status as of Wed 5-10-1995 19:10:41
Data is 31 second(s) old, refresh in 29 second(s)
WARNING: Fan has reached CRITICAL level
Power Supply: 1200W AC
No Intermittent Powerfails
+12 volts measured at
+5 volts measured at
-12 volts measured at -12.05(V)
+24 volts measured at
Airflow temperature measured at 35(C)
Inlet
Arbiter type 1, backplane type 7513 (id 2)
Power supply #1 is 1200W AC (id 1), power supply #2 is removed (id 7)
Active fault conditions: Blower #3
Fan speed is 50%
Active trip points: none
15 of 15 soft shutdowns remaining before hard shutdown
When the system temperature increases above the board shutdown level, a soft shutdown occurs (that is,
Note
the processor modules are shut down, and the power supplies, fans, and CI continue to operate). When
the system cools to the restart level, the system restarts. The system counts the number of times this
occurs and keeps the up/down cycle from continuing endlessly. When the counter reaches zero, the
system performs a hard shutdown, which requires a power cycle to recover. The soft shutdown counter
is reset to its maximum value after the system has been up for 6 hours.
Dbus slots: XX XXXX XXXX
RSP(6)
Shutdown temperature source is 'hotpoint' slot6 (requested slot6)
+12V measured at
+5V measured at
-12V measured at
+24V measured at
+2.5 reference is
Cisco 7500 Series Installation and Configuration Guide
2-34
12.00(V)
5.02(V)
23.70(V)
temperature measured at 26(C)
1
0123456789012
inlet
hotpoint
24C/75F
35C/95F
12.17
5.19
-12.26
24.44
2.49
exhaust
29C/84F
Chapter 2
Preparing for Installation
OL-5008-03 B0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

750775137505

Table of Contents