KROHNE OPTIWAVE-M 7400 C Short Manual page 55

24 ghz radar (fmcw) level transmitter foragitated and corrosive liquids
Table of Contents

Advertisement

OPTIWAVE-M 7400 C
Menu
Function
No.
C6.5.7
Format 2nd
Value
C6.5.8
3rd Value
Variable
C6.5.9
Format 3rd
Value
C7 Device
C7.1 Information
C7.1.1
Tag
C7.1.2
Serial Number
C7.1.3
Device Name
C7.1.4
V Number
C7.1.5
Electronic
Revision
C7.1.6
Software
Revision
C7.1.7
Electronic
Serial No.
C7.1.8
Production Date
C7.1.9
Calibration Date
02/2019 - MA OPTIWAVE-M 7400 C R01 en
Function description
You can change the number of decimal places
that are shown for the second value on the
measurement page in Normal mode. For
example, if you set this menu item to "X.XX",
the value shown will be corrected to 2 decimal
places. If you set this menu item to
"Automatic", the device will adjust the number
of decimal places automatically.
Minimum access level to change the
setting: User
This changes the measurement type of the third
value on the measurement page. This menu
item is only available if you set C6.5.1 Function
to "Three Values".
Minimum access level to change the
setting: User
You can change the number of decimal places
that are shown for the second value on the
measurement page in Normal mode. For
example, if you set this menu item to "X.XX",
the value shown will be corrected to 2 decimal
places. If you set this menu item to
"Automatic", the device will adjust the number
of decimal places automatically.
Minimum access level to change the
setting: User
Use this menu item to read the Tag name.
This is the device fabrication number
This gives the device family name and model
code.
This is the manufacturer's option code for device
configuration.
This is the hardware revision number. This
number agrees with NAMUR NE 53 Guidelines.
This is the software revision number. This
number agrees with NAMUR NE 53 Guidelines.
This is the hardware fabrication number. This
number agrees with NAMUR NE 53 Guidelines.
This the date that the manufacturer finished the
device. The date format is: Year-Month- Day.
This the date that the manufacturer
calibrated the device. The date format is:
Year-Month-Day.
www.krohne.com
OPERATION
Selection list
X, X.X, X.XX, X.XXX,
X.XXXX, X.XXXXX,
X.XXXXXXX
Level, Distance, Sensor
Value, Reflection
2
X, X.X, X.XX, X.XXX,
X.XXXX, X.XXXXX,
X.XXXXXXX, Automatic
Read only
Read only
Read only
Read only
Read only
Read only
Read only
Read only
Read only
4
Marine Default
X.XXX
Reflection
Automatic
TANK01
1
55

Advertisement

Table of Contents
loading