KROHNE OPTISWITCH 3000 C Operating Instructions Manual
KROHNE OPTISWITCH 3000 C Operating Instructions Manual

KROHNE OPTISWITCH 3000 C Operating Instructions Manual

With two-wire output
Hide thumbs Also See for OPTISWITCH 3000 C:

Advertisement

Quick Links

Operating Instructions
OPTISWITCH 3000 C
with two-wire output

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OPTISWITCH 3000 C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for KROHNE OPTISWITCH 3000 C

  • Page 1 Operating Instructions OPTISWITCH 3000 C with two-wire output...
  • Page 2: Table Of Contents

    Disposal ......9 Supplement Technical data......OPTISWITCH 3000 C - with two-wire output...
  • Page 3 Certificates ......Supplementary operating instructions manuals Information: OPTISWITCH 3000 C is available in different versions. Depending on the selected version, supplementary operating instructions manuals may also come with the shipment. The supplementary operating instructions manuals are listed in section "Product description.
  • Page 4: About This Document

    This symbol indicates special instructions for Ex applications. List The dot set in front indicates a list with no implied sequence. à Action This arrow indicates a single action. Sequence Numbers set in front indicate successive steps in a procedure. OPTISWITCH 3000 C - with two-wire output...
  • Page 5: For Your Safety

    (e.g. the VDE regulations in Germany) as well as all prevailing safety regulations and accident prevention rules. 2.5 CE conformity OPTISWITCH 3000 C is in CE conformity with EMC (89/336/ EWG), fulfils NAMUR recommendation NE 21 and is in CE conformity with LVD (73/23/EWG).
  • Page 6: Product Description

    Housing cover Housing with electronics Process fitting 3.2 Principle of operation OPTISWITCH 3000 C is a level sensor with tuning fork for level Area of application detection. It is designed for industrial use in all areas of process technology and is preferably used for bulk solids.
  • Page 7: Operation

    The exact range of the power supply is stated in the "Technical data" in the "Supplement". 3.3 Operation OPTISWITCH 3000 C can detect products with a density >0.08 g/cm³ (>0.003 lbs/in³). On the electronics module you will find the following indicating...
  • Page 8 Product description Storage and transport temperature see "Supplement - Storage and transport tem- perature Technical data - Ambient conditions" Relative humidity 20 … 85 % OPTISWITCH 3000 C - with two-wire output...
  • Page 9: Mounting

    Mounting 4 Mounting 4.1 General instructions In general, OPTISWITCH 3000 C can be mounted in any Switching point position. The instrument must be mounted in such a way that the vibrating element is at the height of the requested switching point.
  • Page 10: Mounting Instructions

    - see illustration a.). In abrasive solids, mounting according to illustration b. has proven. A spout forms in the concave protective sheet preventing wear of the protective sheet. OPTISWITCH 3000 C - with two-wire output...
  • Page 11 filling openings, agitators etc. can occur. To minimise flow resistance caused by the tuning fork, Flows OPTISWITCH 3000 C should be mounted in such a way that the surfaces of the blades are parallel to the product movement.
  • Page 12 This is sufficient to reach the recommended installation position. Fig. 6: Vertical installation - marking Marking on top with screwed version OPTISWITCH 3000 C - with two-wire output...
  • Page 13: Connecting To Voltage Supply

    Select power supply Take note of the general installation regulations. As a rule, connect OPTISWITCH 3000 C to vessel ground (PA), or in case of plastic vessels, to the next ground potential. On the side of the instrument housing there is a ground terminal between the cable entries.
  • Page 14: Wiring Plan, Single Chamber Housing

    Fig. 7: Connection steps 5 and 6 5.3 Wiring plan, single chamber housing Electronics and connection compartment Fig. 8: Electronics and connection compartment DIL switch for mode adjustment Ground terminal Screwed terminals Control lamp OPTISWITCH 3000 C - with two-wire output...
  • Page 15 "Supplement". The wiring example is applicable for all suitable signal conditioning instruments. If the mode switch of OPTISWITCH 3000 C is correctly set to "max.", the control lamp on OPTISWITCH 3000 C lights. red - with submerged vibrating element green - with uncovered vibrating element Take note of the operating instructions manual of the signal conditioning instrument.
  • Page 16: Set Up

    Note: As a rule, always set the mode before starting the setup of OPTISWITCH 3000 C . If the instrument is used in conjunction with a signal conditioning instrument, always set the mode switch (1) on OPTISWITCH 3000 C to max. mode.
  • Page 17: Adjustment Elements

    Vibrating element covered - 16 mA ±1 mA Control lamp for indication of the switching condition. Signal lamp (4) green = 8 mA red = 16 mA red (flashing) = Failure (<2.3 mA) OPTISWITCH 3000 C - with two-wire output...
  • Page 18: Function Chart

    Note: Keep in mind that the mode switch of OPTISWITCH 3000 C must be always set to "max.". You will find suitable signal conditioning instruments under "Technical data"...
  • Page 19 Green Mode A approx. 16 mA Overfill protection Mode B approx. 16 mA Dry run protection Mode B approx. 8 mA Dry run protection Green Fault signal <2.3 mA (mode A/B) flashes red OPTISWITCH 3000 C - with two-wire output...
  • Page 20: Maintenance And Fault Rectification

    Fault rectification many cases, the causes can be determined this way and the faults rectified. OPTISWITCH 3000 C signals "covered" when the vibrating Checking the switching signal element is not submerged (overfill protection) OPTISWITCH 3000 C signals "uncovered" when the...
  • Page 21: Exchange The Electronics

    Maintenance and fault rectification Wrong mode selected à Set the mode switch on OPTISWITCH 3000 C to "max". Set the correct mode on the signal conditioning instrument (A: overfill protection; B: dry run protection). Signal lamp flashes red Electronics has detected a failure à...
  • Page 22: Instrument Repair

    Print and fill out one form per instrument Clean the instrument and pack it damage-proof Attach the completed form and possibly also a safety data sheet to the instrument OPTISWITCH 3000 C - with two-wire output...
  • Page 23: Dismounting

    Correct disposal avoids negative effects to persons and environment and ensures recycling of useful raw materials. Materials: see "Technical data" If you cannot dispose of the instrument properly, please contact us about disposal methods or return. OPTISWITCH 3000 C - with two-wire output...
  • Page 24: Supplement

    - when laid bare approx. 1 s Ambient conditions Ambient temperature on the housing -40 … +80 °C (-40 … +176 °F) Storage and transport temperature -40 … +80 °C (-40 … +176 °F) OPTISWITCH 3000 C - with two-wire output...
  • Page 25 10 … 36 V DC (via the signal conditioning instrument) Electrical protective measures Protection IP 66/IP 67 Overvoltage category Protection class Depending on the version M12x1, according to DIN 43650, Harting, Am- phenol-Tuchel, 7/8" FF. OPTISWITCH 3000 C - with two-wire output...
  • Page 26: Dimensions

    Supplement 9.2 Dimensions OPTISWITCH 3000 C G1½A ø 43mm (1 ") Fig. 12: OPTISWITCH 3000 C, threaded version G1½ A OPTISWITCH 3000 C - with two-wire output...
  • Page 27: Certificates

    Supplement 9.3 Certificates CE declarations of conformity Fig. 13: CE declarations of conformity OPTISWITCH 3000 C - with two-wire output...
  • Page 28 Supplement Manufacturer declaration Fig. 14: Manufacturer declaration OPTISWITCH 3000 C - with two-wire output...
  • Page 29 Supplement OPTISWITCH 3000 C - with two-wire output...
  • Page 30 Supplement OPTISWITCH 3000 C - with two-wire output...
  • Page 31 Supplement OPTISWITCH 3000 C - with two-wire output...
  • Page 32 Subject to change without notice 30061-EN-060830...

Table of Contents