KROHNE OPTIWAVE-M 7400 C Short Manual page 52

24 ghz radar (fmcw) level transmitter foragitated and corrosive liquids
Table of Contents

Advertisement

OPERATION
4
Menu
Function
No.
C5.1.4 HART Variables
C5.1.4.1
Current Out. 1
Var.
C5.1.4.2
HART/sec./CO2
Var.
C5.1.4.3
Tertiary Var.
C5.1.4.4
Quaternary Var.
C6 Display
C6.1
Language
C6.2
Backlight
C6.3
Contrast
C6.4 1st Meas. Page
C6.4.1
Function
C6.4.2
1st Value
Variable
52
Function description
This is the first measurement type shown on
HART® controllers. Make a selection from the
list.
Minimum access level to change the
setting: Expert
This is the second measurement type shown on
HART® controllers. Make a selection from the
list.
Minimum access level to change the
setting: Expert
This is the third measurement type shown on
HART® controllers. Make a selection from the
list.
Minimum access level to change the
setting: User
This is the fourth measurement type shown on
HART® controllers. Make a selection from the
list.
Minimum access level to change the
setting: User
Data can be shown in one of the languages
stored in the device. Make a selection from the
list.
Minimum access level to change the
setting: User
If you set this menu item to "Enabled", a light
comes on when you push a button on the
display keypad and if the loop current is more
than 6 mA.
Minimum access level to change the
setting: User
The contrast control for the display screen. You
can select a shade of grey between light grey (-
10) and black (+10).
Minimum access level to change the
setting: User
This menu item changes the configuration of
data shown on the display screen in Normal
mode. There are two measurement pages
available to show readings in Normal mode.
This setting is for the first page.
Minimum access level to change the
setting: User
This changes the measurement type of the first
value on the measurement page.
Minimum access level to change the
setting: User
www.krohne.com
OPTIWAVE-M 7400 C
Selection list
Level, Distance, Sensor
Value, Reflection
2
Level, Distance, Sensor
Value, Reflection
2
Level, Distance, Sensor
Value, Reflection
2
Level, Distance, Sensor
Value, Reflection
2
English, German, French,
Italian, Portuguese, Spanish,
Czech, Polish, Chinese
(simplified), Japanese,
Russian, Turkish
Disabled, Enabled
min-max:
-10...+10
One Value, One Value &
Bar, Two Values, Two
Values & Bar, Three
Values
Level, Distance, Sensor
Value, Reflection
2
02/2019 - MA OPTIWAVE-M 7400 C R01 en
Marine Default
Distance
Level
Reflection
Sensor Value
English
Enabled
0
One Value &
Bar
Distance

Advertisement

Table of Contents
loading

Table of Contents