Trouble-shooting
The 1264C
EADS North America Defense
Test and Services, Inc. © 1998
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
1. Insert a flat blade screwdriver into the slot in front of the
retaining hook.
2. Gently pry the tab of the retaining hook to the rear, and lift
the card guide, releasing it at the front.
3. Gently pull the card guide forward releasing it from the
center and rear retaining hooks. Bowing the card guide is
required to clear the front rail.
4. To replace, align the card guide with the mainframe front
ensuring that the "V" groove is at the front.
5. Gently push down and to the rear to engage the hooks at
the rear and middle of the card guide. Bowing the card
guide is required to clear the front rail.
6. Allow the front retaining hook to rest on the front rail.
7. Insert a flat blade screwdriver into the slot in front of the
retaining hook.
8. Gently pry the tab of the retaining hook to the rear, and
press down the front of the card guide to snap into position.
To troubleshoot the 1264C VXIbus mainframe to its component
module level use Table 5-1 and Understanding the 1264C in
Chapter 4.
"Fault condition" referenced in the PROBLEM column of Table 5-1
occurs when the monitored system status function (Voltage,
Temperature, or Fan) is outside of its specified tolerance. For
information on status indicators and tolerance limits refer to
Specifications in Appendix A.