Diagnostic Error Codes
Test Error Codes (Continued)
Error Code
XXXX-35
XXXX-36
XXXX-39
XXXX-40
XXXX-41
XXXX-42
XXXX-43
XXXX-44
XXXX-50
XXXX-51
XXXX-52
XXXX-53
XXXX-54
XXXX-60
XXXX-61
XXXX-65
XXXX-90
XXXX-91
XXXX-99
E–12
Description
Invalid SCSI bus phase.
Invalid SCSI bus phase.
Error status from drive.
Target timed out.
SCSI bus stayed busy.
ACK/REQ lines bad.
ACK did not deassert.
Parity error.
Data pins bad.
Data line 7 bad.
MSG, C/D, and/or I/O lines
bad.
BSY never went busy.
BSY stayed busy.
Controller CONFIG-1 register
bad
Controller CONFIG-2 register
bad
Media not unloaded.
Fain failure.
Over temperature.
Autoloader reported tapes not
loaded properly.
Recommended Action
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
1. Ensure fan(s) connected.
2. Replace nonfunctional fan(s).
1. Ensure proper air flow.
2. Perform required maintenance and
cleaning.
1. Install tape(s) in autoloader tape drive
according to test instructions.
2. Change autoloader magazine.