Elba P90 Instructions For The Use page 24

Built-in cooking hobs
Table of Contents

Advertisement

Available languages

Available languages

TABLE FOR THE CHOICE OF THE INJECTORS
BURNERS
Auxiliary (A)
Semi-rapid (SR)
Triple ring (TR)
inner crown
Dual (DB)
outer crowns
(#): Power calculated with inner crown operating.
(
): Power calculated with inner and outer crowns operating.
*
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
BURNERS
Auxiliary (A)
Semi-rapid (SR)
Triple ring (TR)
Dual (DB) -
inner crown operating
Dual (DB) -
inner & outer crowns operating
LUBRICATING THE GAS TAPS
If one of the gas taps becomes hard to turn, dismantle it, thoroughly clean with petrol
and apply special high-temperature grease.
Warning!
These operations must be performed by a specialised engineer.
24
Nominal
Reduced
Power
Power
[Hs - kW]
[Hs - kW]
1,00
0,30
1,75
0,45
3,50
1,50
1,00 (#)
0,32 (#)
4,20 (*)
1,90 (*)
G30/G31
28-30/37 mbar
Ø injector
[1/100 mm]
50
65
95
50
(no. 1 central)
66
(no. 2 outer)
Air necessary for combustion [m
2,00
3,50
7,00
2,00
8,40
G 20
20 mbar
Ø injector
[1/100 mm]
72 (X)
97 (Z)
135 (T)
69 (F1)
(no. 1 central)
102 (Z)
(no. 2 outer)
3
/h x kW)
3
/h]