Set Led Backlite; Exiting The Programming Menu; Temperature Adjust Mode; Thc Tip Calibration - Pace MBT 301 Operation And Maintenance Manual

Digital soldering/desoldering system
Table of Contents

Advertisement

10. Set LED Backlite

Press the UP
and DOWN
1 to 100. Press and release the PROGRAM Key

11. Exiting the Programming Menu

The LED Display now reads "End". The Set-Up Mode procedure is now complete. Choose one
of the following steps:
a) Press and release the UP
b) Press and release the DOWN

Temperature Adjust Mode

To increase or decrease handpiece temperature, press the UP
display will show the current temperature setting for channel "1". Press the UP
arrow keys to increase or decrease handpiece temperature for channel "1". Or press the
PROGRAM Key to move the next channel. After a period of 10 seconds of inactivity, the display will
return to normal operation.
Setting Channel Offset or resetting THC Cal Indicatior (OS mode 2)
To increase or decrease handpiece temperature offset, press the
will show the current temperature offset setting for channel "1". Press the UP
keys to increase or decrease offset temperature for channel "1". Or press the
move the next channel. After a period of 10 seconds of inactivity, the display will return to normal
operation.

THC Tip Calibration

To enter Calibration mode: Press and hold the
powering on unit. Release keys when "Software Version" appears. Follow the instructional prompts
to review or set each menu option. Follow the procedure below.
Calibration Instructions
The steps for the procedure are:
1. Turn on the system.
2. Clear any offset from the system by disconnecting the handpiece from the system. Re- connect the
handpiece and proceed to step 2.
3. A BLINKING dot will appear in the center of the "C" in channel ("CH"). Set the MBT 301 to 700°F to
(370°C).
4. Measure the actual temperature of the tip from your temperature verification device.
Note results.
5. Turn off the system.
6. Enter Calibration mode: Press and hold the
turning the system on. Release both keys when the display reads version 1.2 or higher.
7. The display will now read Channel "1" System Cal? Press the
the measured temperature from step 4 for channel "1". For example, your temperature
verification device reads 695 °F. Scroll through until the display reads 695. Press
move to the next channel.
8. Press the
PROGRAM Key to save calibration and move to the next channel. Upon exiting,
LED will illuminate green and the display will return to normal operation mode.
9. See calibration options in the THC Calibration Offset Mode Select section of the manual.
©2013 PACE Worldwide, Southern Pines, North Carolina All Rights
 
to enter increase or decrease LCD contrast. The range of backlite is
to move to the next step.
Key to exit Set-Up Mode and return to normal operation.
Key to return to the start of the Set-Up Mode procedure.
PROGRAM Key and the
PROGRAM Key and the
or DOWN
arrow key once. The
or
PROGRAM Key once. The display
or
DOWN
PROGRAM Key to
UP keys while
UP key while
UP or
DOWN key to enter
DOWN
arrow
key / NO to
Page 18 of 18