SERVICE SPECIFICATIONS AND
STANDARDS
Description
Glow plug indicator (Quick-heat type) for L3
Type
Model
Rated current
Voltage across terminals (at 29A)
Fuel cutoff solenoid
Type
Coil resistance
Working voltage
Stroke
Temperature range
Fuel cutoff solenoid
Type
Rated voltage
Rated temperature
Coil resistance
Rated pull current
Rated hold current
Control timer
Input voltage
Load
Working temperature
Glow timer
Model
Rated voltage
Working temperature
Initial characteristic
(Normal temperature, normal
humidity, Vcc = 12V)
Environmental characteristic
(–30°C to 70°C [–22°F to 158°F],
Vcc = 7 to 15V)
Glow relay
Model
Rated voltage
Continous rating
Coil resistance
Inductance
Working temperature
Service Manual Mitsubishi L-Series diesel engines
Version 08/2004
SPECIFICATIONS AND MAINTENANCE
Specification and Standard
Red-hot type
DH-139V-29
29A
1.7V±0.2V
Electromagnetic ETS push type
1.6 Ω±10% (at 20°C [68°F])
10 to 15V DC
10±0.5 [0.3937±0.0197]
–30 to 120°C [–22 to 248°F]
Electromagnetic ETR pull type
12V DC
20°C [68°F]
Pull 0.25 Ω±10% Hold 13.5 Ω±10%
55A
1A
9V to 15V DC
Solenoid (Coil resistance 1.7 Ω or more)
–30 to 80°C [–22 to176°F]
S81NJ
12V DC
–40 to 85°C [–40 to 185°F]
+1.4
6
sec.
-0
+2.0
6
sec.
-0.6
G71S P
12 V DC
1 minute
13 Ω
24 mH (at 1 KHz)
-40 to 100°C [-40 to 212°F]
(70 to 100°C [158 to 212°F] for 20 sec. or less
continued use)