SPECIFICATIONS AND MAINTENANCE
STANDARDS
Description
Starter for L2
Type
Model
Voltage–output
Direction of rotation
No-load characteristics
Terminal voltage
Current
Speed
Load characteristics
Terminal voltage
Current (torque)
Speed
Pinion gap
Thrust gap
Starter for L3
Type
Model
Voltage–output
Direction of rotation
No-load characteristics
Terminal voltage
Current
Speed
Load characteristics
Terminal voltage
Current (torque)
Speed
Pinion gap
Thrust gap
Alternator
Type
Model
Voltage-output
Direction of rotation
Output characteristic (Hot)
Terminal voltage
Current/Speed
Regulated voltage
Glow plug (Quick-heat type)
Type
Model: Y-145T
Voltage–current
Resistance
Glow plug indicator (Quick-heat type) for L2
Type
Model
Rated current
Voltage across terminals (at 19A)
150 / 155
38.6 Electrical System
Specification and Standard
Solenoid shift type
M000T60481 (30L66-10600)
12V–1.2 kW
Clockwise as viewed from pinion side
11V
90A or less
2500 RPM or more
7.5V
300A (10.5 N·m (1.07 kgf·m) [7.7 lbf·ft] or more)
850 RPM or more
0.5 to 2.0 [0.0197 to 0.0787]
0.5 [0.0197] or less
Solenoid shift type
M001T68381 (30L66-10500)
12V–1.7 kW
Clockwise as viewed from pinion side
11V
110A or less
2400 RPM or more
7.7V
400A (16.0 N·m (1.63 kgf·m) [11.8 lbf·ft] or more)
740 RPM or more
0.5 to 2.0 [0.0197 to 0.0787]
0.5 [0.0197] or less
AC type with built-in IC regulator
A007TA01718 (30A68-00801)
12V–40 A
Clockwise as viewed from pulley side
13.5V
21A/ 2500 RPM
37A/5000 RPM
14.7±0.3V
Sheath type
(With hex nut)
10.5V–9.7A
0.2 Ω
Red-hot type
DH-139V-19
19A
1.5V±0.2V
ENGLISH
SERVICE SPECIFICATIONS AND
Repair Limit Service Limit
Service Manual Mitsubishi L-Series diesel engines
STANDARDS
Unit: mm (in.)
11.5 [0.4528]
0.7 [0.0276]
11.5 [0.4528]
0.7 [0.0276]