STARTER
Battery
Figure 122 Attraction test
Battery
Figure 123 Holding test
Battery
Figure 124 Return test
124 / 155
Starter
Body
Starter
Body
Starter
ENGLISH
ELECTRICAL SYSTEM
2.
Attraction test. Connect a battery to the magnetic
switch terminal S and M. The pinion must protrude.
CAUTION
Do not apply battery current for more than 10
seconds.
3.
Holding test. With a battery connected to the
magnetic switch terminal "S" and to the starter
body, manually pull out the pinion fully. The pinion
must remain at that position when released from
holding by hand.
CAUTION
Do not apply battery current for more than 10
seconds.
4.
Return test. With a battery connected to the
magnetic switch terminal "M" and to the starter
body, manually pull out the pinion fully. The pinion
must return to its original position when released
from holding by hand.
CAUTION
Do not apply battery current for more than 10
seconds.
Service Manual Mitsubishi L-Series diesel engines