Supermicro SuperServer SYS-1029U-TN12RV User Manual page 147

Table of Contents

Advertisement

Monitor health
Current non-critical threshold status
Controller temperature: within the non-critical threshold on all DIMMs.
Media temperature: within the non-critical threshold on all DIMMs.
Percentage remaining: within the non-critical threshold on all DIMMs.
Modify non-critical thresholds
Controller temperature [C]
Use this feature to set controller temperature in Celsius. (Min. = 20°C, Max. = 105°C)
Media temperature [C]
Use this feature to set media temperature in Celsius. (Min = 20°C, Max = 85°C )
Percentage remaining [%]
Use this feature to set spare capacity as a percentage. (Min = 1%, Max = 99%)
Apply changes
Back to main menu
Update firmware
Specify the firmware image to load on the DIMMs on the next system restart and
select Update.
Current firmware version: 01.00.00.5127
Selected firmware version: None
File:
Press <Enter> and type in the file path relative to the root directory of the device contain-
ing the new firmware image file, such as "\firmware\newFirmware.bin".
Staged firmware version: N/A
Update
Back to main menu
147