Code 128 Set Length 2; Code 128 Stitching - Datalogic Heron HD3100 Product Reference Manual

Linear imager
Table of Contents

Advertisement

Symbologies

Code 128 Set Length 2

This feature specifies one of the bar code lengths for
on page
page 133
Mode. Length includes the bar code's data characters only.
The length can be set from 1 to 80 characters. A setting of 00 specifies to
ignore this length (only one fixed length). See
more detailed programming instructions.
Select Code 128 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.

Code 128 Stitching

This option enables/disables stitching for Code 128 labels. When parts of a
Code 128 bar code are presented to the scanner with this feature enabled, the
bar code parts will be assembled by the scanner's software, and the data will be
decoded if all bar code proofing requirements are met.
$CC8ST01
Code 128 Stitching = Enable
Product Reference Guide
133. Length 2 is the maximum label length if in
Mode, or the second fixed length if in
$CC8L2
80 = Length 2 is 80 Characters
DEFAULT
Enter/Exit Programming Mode
Code 128 Length Control
Fixed Length on page 133
"Set Length 2"
To configure this feature, scan the ENTER/EXIT bar code
above, then the bar code at left followed by digits from
the Alphanumeric characters in
pad
representing your desired character(s). End by
scanning the ENTER/EXIT bar code again.
CANCEL
$CC8ST00
Code 128 Stitching = Disable
DEFAULT
Variable Length on
on page 247 for
Appendix D, Key-
~
135