RGB Auto Delay Time
Specifies the delay time for running the RGB auto mode after the scanner has
gone into an idle state (no label reading, label programming or communication
with Host).
The delay can be set within a range of zero (0) to 255 milliseconds (5 seconds)
in 500ms increments. The value 0x00 means Auto Mode is disabled.
To set the time:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 500 (setting is in 500ms increments). Pad the
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
4. Go to
5. Scan the appropriate two digits from the keypad in
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
This completes the procedure. See the following table for examples of how to
set this feature.
Table 17. RGB Auto Delay Examples
STEP
ACTION
1
Desired Setting
2
Divide by 500
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT RGB AUTO DELAY TIME
Scan Two Characters From
5
Appendix D, Keypad
6
Scan ENTER/EXIT PROGRAMMING MODE
240
result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05,
20 = 20, etc.
ming Mode.
page 79
and scan the bar code: SELECT RGB AUTO DELAY TIME.
represent the duration which was determined in the steps above.
If you make a mistake before the last character, scan the CANCEL bar code
to abort and not save the entry string. You can then start again at the
beginning.
EXAMPLES
500ms
01
'0' and '1'
10,000ms (10
1,000ms (1 sec.)
sec.)
02
20
'0' and '2'
'2' and '0'
Appendix D,
Keypad, that
60,000ms (60 secs.)
120
'1', '2' and '0'