TRENDnet TI-RP262i User Manual page 86

Managed industrial l2
Hide thumbs Also See for TI-RP262i:
Table of Contents

Advertisement

TRENDnet User's Guide
0x0020
16 words
ASCII
0x0040
7 words
0x0050
12 words
ASCII
© Copyright 2018 TRENDnet. All Rights Reserved.
Word 1 Lo byte = 'D'
Word 2 Hi byte = 'E'
Word 2 Lo byte = 'F'
Word 3 Hi byte = 'G'
Word 3 Lo byte = ' '
Word 4 Hi byte = 'C'
Word 4 Lo byte = 'o'
Word 5 Hi byte = 'r'
Word 5 Lo byte = 'p'
Word 6 Hi byte = '.'
Word 6 Lo byte = '\0'
Product Name = "SWITCH"
Word 0 Hi byte = 'S'
Word 0 Lo byte = 'W'
Word 1 Hi byte = 'I'
Word 1 Lo byte = 'T'
Word 2 Hi byte = 'C'
Word 2 Lo byte = 'H'
Product Serial Number
Ex: Serial No=A000000000001
Firmware Version=" 8648-999-
1.1.0.S0"
Word 0 Hi byte = '8'
Word 0 Lo byte = '6'
Word 1 Hi byte = '4'
Word 1 Lo byte = '8'
Word 2 Hi byte = '-'
Word 2 Lo byte = '9'
Word 3 Hi byte = '9'
Word 3 Lo byte = '9'
0x0060
16 words
ASCII
0x0070
3 words
HEX
0x0080
1 word
HEX
0x0081
1 word
HEX
Managed Industrial L2 Switch
Word 4 Hi byte = '-'
Word 4 Lo byte = '1'
Word 5 Hi byte = '.'
Word 5 Lo byte = '1'
Word 6 Hi byte = '.'
Word 6 Lo byte = '0'
Word 7 Hi byte = '.'
Word 7 Lo byte = 'S'
Word 8 Hi byte = '0'
Word 8 Lo byte = '\0'
Firmware Release Date=" Mon Sep 30
18:51:45 2013"
Ethernet MAC Address
Ex: MAC = 00-01-02-03-04-05
Word 0 Hi byte = 0 x 00
Word 0 Lo byte = 0 x 01
Word 1 Hi byte = 0 x 02
Word 1 Lo byte = 0 x 03
Word 2 Hi byte = 0 x 04
Word 2 Lo byte = 0 x 05
Power 1(PWR) Alarm, DIP switch 1
need ON
0x0000: no alarm
0x0001: input voltage < 44V
0x0002: input voltage > 57V
0x0003: No PWR input
Power 2(RPS) Alarm, DIP switch 1
need ON
0x0000: no alarm
0x0001: input voltage < 44V
83