TRENDnet User's Guide
Terminal Block
Redundant power inputs, alarm relay contact, 6-pin
Wire range: 0.5 mm^2 to 2.5 mm^2
Solid wire (AWG): 12-26
Stranded wire (AWG): 12-26
Wire strip length: 10-11mm
DIP Switch
Switch
Status
Function
1
OFF
Disable alarm relay for PWR power input
ON
Enable alarm relay for power failure on PWR power
input
2
OFF
Disable alarm relay for RPS power input
ON
Enable alarm relay for power failure on RPS power input
3
OFF
Storm control managed by switch configuration
ON
Enable storm control (Broadcast and DLF rate set to
300pps)
Takes precedence over storm control switch
configuration
4
OFF
802.1p QoS managed by switch configuration
ON
Enable 802.1p QoS on ports 1 and 2 (Set CoS priority to
tag 4 on ports 1 and 2)
Takes precedence over 802.1p QoS switch configuration
5
OFF
Port 9 SFP set to Gigabit speed full duplex
ON
Port 9 SFP set to 100Mbps speed full duplex
6
OFF
Port 10 SFP set to Gigabit speed full duplex
ON
Port 10 SFP set to 100Mbps speed full duplex
© Copyright 2018 TRENDnet. All Rights Reserved.
Alarm Relay Output
Relay output with current carrying capacity of 1A, 24V DC
Short circuit mode when one power source is connected
Open circuit mode when two power sources are connected
Enclosure
IP30 rated metal enclosure
Fanless passive cooling
DIN-Rail mount
Grounding point
ESD (Ethernet) Protection: 8KV DC
Surge (Power) Protection: 2KV DC
MTBF
617,085 hours @ 25° C
113,378 hours @ 75° C
Operating Temperature
-40° – 75° C (-40° – 167° F)
Operating Humidity
Max. 95% non-condensing
Dimensions
160 x 120 x 50mm (6.3 x 4.72 x 1.97 in.)
Weight
884g (1.95 lbs.)
Certifications
CE
FCC
Shock (IEC 60068-2-27)
Freefall (IEC 60068-2-32)
Vibration (IEC 60068-2-6)
Managed Industrial L2 Switch
156

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ti-pg102iTi-pg102i-mTi-g642iTi-g102iTi-g160wsTi-g160i

Table of Contents