TRENDnet TI-RP262i User Manual page 75

Managed industrial l2
Hide thumbs Also See for TI-RP262i:
Table of Contents

Advertisement

TRENDnet User's Guide
ERPS revertive and non-revertive switching
ERPS considers revertive and non-revertive operation. In revertive operation, after the
condition(s) causing a switch has cleared, the traffic channel is restored to the working
transport entity, i.e. blocked on the RPL. In the case of clearing of a defect, the traffic
channel reverts after the expiry of a WTR timer, which is used to avoid toggling
protection states in case of intermittent defects. In non-revertive operation, the traffic
channel continues to use the RPL, if it is not failed, after a switch condition has cleared.
Control VLAN:
The pure ERPS control packets domain only, no other packets are transmitted in this
vlan to guarantee no delay for the ERPS. So when you configure a Control VLAN for a
ring, the vlan should be a new one. The ERPS will create this control vlan and its
member ports automatically. The member port should have the Left and Right ports
only.
In ERPS, the control packets and data packets are separated in different vlans.
The control packets are transmitted in a vlan which is called the Control VLAN.
Instance:
For ERPS version 2, the instance is a profile specifies a control vlan and a data vlan or
multiple data vlans for the ERPS. In ERPS, it can separate the control packets and data
packets in different vlans. The control packets is in the Control VLAN and the data
packets can be in one or multiple data vlan. And then user can assign an instance to an
ERPS ring easily.
In ERPS version 1, if a port is blocked by ERPS, all packets are blocked.
In ERPS version 2, if a port is blocked by a ring of ERPS, only the packets belong to the
vlans in the instance are blocked.
Notice:
Control VLAN and Instance:
In CLI or Web configurations, there are the Control VLAN and the Instance settings.
If the Control VLAN is configured for a ring and you want to configure an instance for the
ring. The control vlan of the instance must be same as the Control VLAN; otherwise, you
© Copyright 2018 TRENDnet. All Rights Reserved.
will get an error. If you still want to use this instance, you can change the Control VLAN
to same as the control vlan of the instance first. And then configures the instance.
CLI Configuration
Node
Command
enable
show erps
enable
show erps instance
enable
show erps instance
INSTANCE_ID
configure
erps enable
configure
no erps enable
configure
erps ring-id VALUE
configure
erps instance
configure
no erps ring-id VALUE
erps-ring
show
erps-ring
control-vlan
erps-ring
guard-timer
erps-ring
holdoff-timer
Managed Industrial L2 Switch
Description
This command displays the ERPS
configurations.
This command displays the ERPS instance
configurations.
This command displays the specific ERPS
instance configurations.
This command enables the global ERPS on
the Switch.
This command disables the global ERPS on
the Switch.
This command creates an ERPS ring and its
ID and enter ERPS node.
This command enters the instance
configure node.
This command creates an ERPS ring and
enter ERPS node to configure detail ring
configurations.
This command displays the configurations
of the ring.
This command configures a control-vlan
for the ERPS ring.
This command configures the Guard
Timerfor the ERPS ring. (default:500ms)
This command configures the Hold-off
Timer for the ERPS ring. (default:0 ms)
72

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ti-pg102iTi-pg102i-mTi-g642iTi-g102iTi-g160wsTi-g160i

Table of Contents