IUH-F190-V1-*, IUT-F190-R4-V1*
Operation
Read Parameters
The RP command reads configuration parameters from the read/write head.
Command:
Response:
<SystemCode> = U
<ParamTyp> = 2 bytes ASCII
<DataLength> = Length of <Data> in command, 2 bytes binary
<Data> = Optional additional information
Example:
RP1UE5.00.00 outputs the number of unsuccessful read attempts until status 5.
Write Parameters
Command WP writes configuration parameters to the read/write head.
Command:
Response:
<SystemCode> = U
<ParamTyp> = 2 bytes ASCII
<DataLength> = Length of <Data>, 2 bytes binary
<Data> = Optional additional information
Example:
WP1UE5.00.01.05 sets the number of unsuccessful read attempts to status 5 on 5 attempts.
6.6.2

Parameters

Antenna Polarization AP
This parameter switches polarization to horizontally linear, vertically linear, or combined mode,
or reads out the polarization currently set.
ParamTyp:
Default:
Value range:
1.Combined horizontally linear and vertically linear for each read/write attempt
Example:
WP1UAP.00.01H switches the polarization to horizontally linear
WP1UAP.00.01C switches the polarization to combined mode
RP1UAP.00.00 reads out the set polarization
for IUH-*
ASCII
for IUH-*
ASCII
RP <ChanNo> <SystemCode> <ParamTyp>
<DataLength> <Data> <CHCK> <ETX>
<Status> <ChanNo> <Data> <CHCK> <ETX>
WP <ChanNo> <SystemCode> <ParamTyp>
<DataLength> <Data> <CHCK> <ETX>
<Status> <ChanNo> <CHCK> <ETX>
AP
AP = C
1
C = combined
H = Horizontally linear
V = Vertically linear
49