IUH-F190-V1-*, IUT-F190-R4-V1*
Operation
6.6.1
Read and Write Parameters
With the read parameter (RP) and write parameter (WP) configuration commands, you can
read/write the following parameters:
Abbreviation
AP
CD
E5
FL
IF
MB
MD
MF
NC
NT
PT
QV
QW
RC
RD
SM
TA
The parameters are saved in the read/write head as nonvolatile.
48
Page
See "Antenna Polarization AP" on
page 49
See "CD Transmission Channels" on
page 50
See "Number of Unsuccessful
Attempts until Status 5 "Enhanced
Status 5" E5" on page 50
See "Read Out Filter Mask "Filter List"
FL" on page 51
See "Output Additional Information,
"Information" IF" on page 51
See "Memory Module for Tag
Accesses to the "Memory Bank" MB"
on page 52
See "Retrieve Additional Information
MD" on page 52
See "Measurement of Reflected
Transmitting Power "Measure
Reflection" MF" on page 52
See "Number of Channels NC" on
page 53
See "Search Algorithm Cancellation
Criteria "number of tags to find" NT"
on page 53
See "Transmission Power "Power
Transmit" PT" on page 54
See "Protocol Mode QV" on page 55
See "Q Value QW" on page 57
See "Country Identifier, "Region
Code"" on page 57
See "Reset to Default, RD" on page 58 Writeable
See "Transmission Pauses in
"Sensing Mode" SM" on page 59
See "Number of Attempts "Tries
Allowed" TA" on page 59
Parameter is readable/writeable
Readable/writeable
Readable/writeable for RC = 1, 4, 5, 6,
8
Readable for RC = 2, 3, 7, 9, 10, 11,
12, 13, 14
Readable/writeable
Readable
Readable/writeable
Readable/writeable
Readable
Readable
Readable/writeable for RC = 2, 3, 7, 9,
10, 11, 12, 13, 14
Readable for RC = 1, 4, 5, 6, 8
Readable/writeable
Readable/writeable
Readable/writeable
Readable/writeable
Readable
Readable/writeable
Readable/writeable