Sensor Settings; Operation Via The Command Interface - Pepperl+Fuchs IUT-F190-R4-V1 Series Manual

Uhr read/write head for identcontrol
Hide thumbs Also See for IUT-F190-R4-V1 Series:
Table of Contents

Advertisement

IUH-F190-V1-*, IUT-F190-R4-V1*
Commissioning
<WordAddr>:
<WordNum>:
5.2

Sensor Settings

Warning!
Device not configured or configured incorrectly
Configure the device prior to commissioning. A device that has not been configured or
configured incorrectly may lead to faults in the plant.
You must configure the control interface before commissioning the IUH-F190-V1-* read/write
head. To do so, refer to the "Commissioning" chapter of the manual for your control interface.
Configure the read/write heads with the described system commands (see chapter 6.6.1). For
a parameterization example, see see chapter 5.3.
Caution!
Uncontrolled triggered processes
Before commissioning the device, make sure that all processes are running smoothly;
otherwise damage may occur in the plant.
5.3

Operation via the Command Interface

This section shows you how to commission the IUH-F190-V1-* read/write head using an
IDENTControl control interface with serial interface. The commissioning procedure described
relates to the RS-232 interface and involves a PC. The examples include the syntax for coding
the commands and parameters via the Ethernet TCP/IP and PROFIBUS/PROFINET
interfaces. Further details about these codes and the factory settings for your IDENTControl
control interface can be found in the corresponding manual.
The commissioning of the IUT-F190-R4-V1-* read/write head with integrated RS-485 interface
is also carried out using the above commands and parameters. For details regarding the IUT
F190-R4-V1-* read/write head see chapter 6.7
Example:
In the examples below, the read/write head is connected to channel 1 of the control interface.
The outputs follow the multiframe protocol, see table "Responses Depending on Protocol
Mode QV" on page 56.
Reading Tags
Enhanced Read Read-Only Code
Send the enhanced read read-only code command to the read/write head. The "RF ON" LED
on the read/write head lights up blue.
Command:
Confirmation:
Response:
Table 5.1
34
Word start address in the read/write tag, 4 hex
from "0000h" to "FFFF", depending on tag type
Number of words to be read or written, 2 hex
from "01" through "20" depending on the tag type, word lengths are 4
bytes
Serial
EF1
-
.35.31
Enhanced read read-only code, no tag in the detection range
Ethernet
.00.04.1D.03
.00.06.1D.03.FF.0B
.00.06.1D.03.05.0C
characters, range
ASCII
characters. Range
ASCII
PROFIBUS/PROFINET
.1D.03
.1D.03.FF.0B
.1D.03.05.0C

Advertisement

Table of Contents
loading