Pepperl+Fuchs IUT-F190-R4-V1 Series Manual page 59

Uhr read/write head for identcontrol
Hide thumbs Also See for IUT-F190-R4-V1 Series:
Table of Contents

Advertisement

IUH-F190-V1-*, IUT-F190-R4-V1*
Operation
Abbreviation
NC
NT
PT
QV
QW
RC
RD
SM
TA
Transmission Pauses in "Sensing Mode" SM
The parameter SM defines a pause time in milliseconds. This pause time is executed once all
runs are complete.
This parameter is especially useful for continuous operation with "enhanced" commands (see
chapter 6.4). If you specify transmission pauses, you can operate the read/write head at higher
ambient temperatures.
ParamTyp:
Default:
Value range:
1.For all FR1 read/write heads
2.For all FR2 read/write heads
3.For all FR1 read/write heads
4.For all FR2 read/write heads
Example:
WP1USM.00.02.27.10 sets the pause time to 10,000 ms = 10 seconds.
RP1USM.00.00 reads out the pause time.
Number of Attempts "Tries Allowed" TA
This parameter sets the permitted number of write or read attempts, or outputs the permitted
number of attempts.
ParamTyp:
Default:
Value range:
Example:
WP1UTA.00.01.01 permits precisely one attempt (= no repeats)
Parameter
Number of Channels
Search Algorithm
Cancellation Criteria
Power Transmit
Protocol Mode QV
Q Value
Country Identifier, "Region
Code"
Reset to Default
Transmission Pauses in
"Sensing Mode"
Number of Attempts, "Tries
Allowed" TA
TA
TA = 2
1 ... 255
Default value
Depending on the country-specific settings,
see chapter 3.3
Off (255)
Depending on the country-specific settings,
see chapter 3.3
Multiframe Protocol (M)
2
Not applicable
Not applicable
0
2
SM
1
SM = 100 ms
2
SM = 0 ms
100 ms ... 65,535 ms, 2 bytes
0 ms ... 65,535 ms, 2 bytes
3
4
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iuh-f190-v1 seriesIuhf190v1b

Table of Contents