2.4 DIP SWITCH SETTINGS

Open the cover of the DIP switches on the bottom
of the cradle in order to reach the DIP switches.
• Turn the DIP switch ON by moving it upwards.
• Turn the DIP switch OFF by moving it downwards.
Single cradle DIP switch settings:
DIP
ON
Switch
SW 1
Baud rate *
SW 2
Baud rate *
SW 3
Baud rate *
SW 4
SW 5
SW 6
Auto-baud
rate (PC-
controlled)
Multicradle DIP switch settings:
DIP
ON
Switch
SW 1
Baud rate *
SW 2
Baud rate *
SW 3
Baud rate *
SW 4
RS232/
RS485
SW 5
Cascade **
SW 6
RS485
termination
ON
SW 7
SW 8
OFF
Baud rate *
Baud rate *
Baud rate *
Spare
Spare
SW 1, 2, 3
determines
baud rate.
OFF
Baud rate *
Baud rate *
Baud rate *
RS232 only
RS485
Termination
OFF
Factory
setting
Factory
setting
* Set baud rate as in table below.
** In typical use keep cascade switch SW5 off.
User baud rate settings:
*) Baud rate
2400
4800
9600 (default)
19200
38400
57600
115200
OPL972X/CRD972X OPTICON - 17
SW
SW
SW
1
2
3
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
ON