7.5. Curvature

With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R≥15
mm.
With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R≥20
mm.
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
PCS = 0.9, Resolution = 0.26 mm, Quiet Zone = 10 mm
Distance:
Angle:

8. Interface Specifications

8.1. RS-232C Interface Specification

Settings and Communication

8.1.1.
Reading the menu barcodes in section 10.1 can set the RS-232C interface
default.
Start/stop bits
Flow control time out
Communication settings can be configured by scanning corresponding menu
barcodes.

Figure 7: Curvature

60 mm from the edge of the scanner
Skew Angle β = +15°
Parameter
Baud rate
Data bits
Parity bits
Handshaking
[U2] setting
9600 bps
1 bit
8 bits
No parity
No handshake
Indefinitely