7.5. Curvature
With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when
R = 15 mm.
With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when
R = 20 mm.
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
PCS = 0.9, Resolution = 0.26 mm, Quiet Zone = 10 mm
Distance:
Angle:
8. Interface Specifications
8.1. RS-232C Interface
Settings and Communication
8.1.1.
Reading the menu barcodes in section 10.1 can set the RS-232C interface
default.
Start/stop bits
Flow control time out
You can change the communication condition using the menu barcode.
70 mm from the front edge of the scanner
Skew Angle β = +15°
Item
Baud rate
Data bits
Parity bits
Handshaking
Figure 7: Curvature
[U2] setting
9600 bps
1 bit
8 bits
No parity
No handshake
Indefinitely
17
Opticon
OPR 2001
Specifications Manual