8. Interface Specifications

8.1. RS-232C Interface Spec

Settings and Communication

8.1.1.
Reading the menu barcodes in section 10.1 can set the RS-232C interface
default.
Flow control time out

Signal Level

8.1.2.
Signal Name

Pin Assignment

8.1.3.
Item
Baud rate
Start/stop bits
Data bits
Parity bits
Handshaking
I/O
SC
OUT
RD
IN
RS
OUT
CS
IN
TRIGGER
IN
Signal
F.GND
Shield (Black)
S-GND
VCC (+5V)
SD
RD
RS
CS
TRIGGER
[U2] setting
9600 bps
1 bit
8 bits
No parity
No handshake
Indefinitely
RS-232C Level (V)
Mark/OFF
Space/ON
-5 to -15
+5 to +15
-3 to -15
+3 to +15
-5 to -15
+5 to +15
-3 to -15
+3 to +15
Low active
Pin
Brown
Orange
Green
White
Grey
Blue
Yellow
17