ABB HT842305 Operation Manual page 59

Table of Contents

Advertisement

Operation Manual / TPL85-B14/-B15/-B16
5 Maintenance / 5.4 Cleaning the compressor during operation
5.4.2 Wet cleaning using vacuum cleaning device on filter
© Copyright 2018 . All rights reserved.
silencer (XC4)
In order to carry out a successful cleaning procedure that has been
tested and is recommended by ABB Turbo Systems, the following pre-
requisite must be met:
Engine load 25 ... 85%
w
If the engine compartment temperature is less than 0°C during wet
w
cleaning of the compressor, precautionary measures must be taken
to prevent ice formation.
Start cleaning cycle according to following description Wet cleaning
u
operation with XC4.
Procedure for compressor wet cleaning with XC4
01Cleaning medium vessel
03Injection pipe
05Cover
NOTICE
When using the cleaning medium vessel on the filter silencer, refer to
the detailed cleaning instructions on the sign (04) attached to the filter
silencer.
HZTL2491_EN
02Pipe
04Cleaning instructions
06Valve
Revision C
August 2018

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tpl85-b14

Table of Contents