Operation Manual / TPL85-B14/-B15/-B16
4 Operation / 4.3 Servicing work
4.3.1 Service work every 25 ... 50 hours
© Copyright 2018 . All rights reserved.
CAUTION
Shortened service intervals
Despite observance of the service intervals, unusual loads, such as sev-
eral start-stops a day, harsh environmental factors, poor fuel quality or
heavy installation vibration can lead to premature machine damage.
A shortened service interval must be arranged with ABB Turbo Sys-
u
tems.
NOTICE
Service inspection after 5 years
To prevent age- and stoppage-related machine damage, an inspection
by an ABB Turbocharging Service Station is recommended at the latest
5 years after the last service.
Visual inspection for air, exhaust gas, water and oil leaks.
u
Record operating data and enter it in the engine logbook.
u
Clarify the cause of any variances.
u
CAUTION
Unknown changes during operation
The consequences can range from an impairment to a breakdown.
Have unknown causes clarified by an ABB Turbocharging service sta-
u
tion.
HZTL2491_EN
Revision C
August 2018