Suggestion for noise insulation of the bellows
01
Compressor casing
02
Bellows
03
Charge air duct / scavenging
air line
The permitted air inlet temperature must be between -40C°... +45C°.
Service work to be carried out during operation involves visual checks,
monitoring, measuring, inspection work and functional checks. It is then
possible for changes to the turbocharger to be identified and rectified.
In this way, it can be ensured that the turbocharger remains in full work-
ing order.
CAUTION
Service intervals
Service work on the turbocharger that is neglected or carried out too
late can lead to excessive contamination and wear as well as operating
failures.
Carry out service work at specified time intervals.
u
HZTL2491_EN
04
Insulation pads
05
Insulation mat (at least 15 mm)
06
Sheet metal cover