ABB HT842305 Operation Manual page 49

Table of Contents

Advertisement

Operation Manual / TPL85-B14/-B15/-B16
5 Maintenance / 5.2 Cleaning the filter silencer
If provided
© Copyright 2018 . All rights reserved.
Removing and cleaning the filter silencer
Remove filter ring (81265).
u
Rinse the filter ring (81265) using water with detergent additive or, if
u
it is heavily contaminated, soak and carefully push through. Rinse in
cold water. Avoid high mechanical stress (do not use a water jet).
NOTICE
The amount of filter ring (81265) contamination depends on the cleanli-
ness of the air that is drawn in. Clean filter ring after every 500 hours of
service or more frequently if necessary.
Loosen the tension bands (81270) at the locks (81271) and remove
u
them along with the cover grids (81266) and connecting strips
(81268).
NOTICE
If the cleaning medium vessel is attached to the filter silencer (option
depends on type of turbocharger), the water injection pipe must first
be removed at one insert unit (E) (see also the following section Disas-
sembling the cleaning pipe).
Pull out insert units (E), bend open sheet-metal coverings (81137),
u
then take out absorption segments (81136).
Clean the absorption segments (81136).
u
During cleaning, ensure that the absorption segments (81136) are
only cleaned with a mild jet of compressed air, soft brush or a damp
cloth. Otherwise there is a risk of damage or deformation.
NOTICE
Replace heavily contaminated absorption segments, filter ring and
damaged connecting strips with original parts from ABB Turbo Sys-
tems.
HZTL2491_EN
Revision C
August 2018

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tpl85-b14

Table of Contents