2 MAINTENANCE, TROUBLESHOOTING
2.6

Alarm Status

The alarm status log shows the date and time alarms were violated.
1. Press the [MENU] key to open the main menu.
2. Press the [3] key to choose OWN DATA.
3. Press the [3] key to choose ALARM STATUS.
4. Use the [▼] or [▲] key to scroll the log.
5. Press the [MENU] key to close the log.
Alarm Status
Indication
TX
ANT
CH1
CH2
CH70
EPFS
L/L
SOG
COG
HDG
ROT
34
[ALARM STATUS]
EPFS
Alarm name,
L/L
date and time
SOG
of alarm
COG
HDG
ROT
ALARM STATUS display
Alarm statuses and their meanings
Alarm
Message
Tx malfunction
Antenna VSWR
exceed limit
Rx channel 1
malfunction
Rx channel 2
malfunction
Rx channel 70
malfunction
External EPFS lost
No sensor
positioning in use
No valid SOG
information
No valid COG
information
Heading lost/invalid Invalid/nonexistent HDG data
No valid ROT
information
7/MAR
4:32:16
7/MAR
4:02:01
7/MAR
2:34:54
6/MAR
7:09:32
3/MAR
8:00:21
19/FEB
9:05:22
Meaning
TX malfunction
Antenna VSWR trouble. Continued
operation possible.
TDMA RX1 Board trouble. TX stopped
on corresponding TX channel.
TDMA RX2 Board trouble. TX stopped
on corresponding TX channel.
DSC RX Board trouble, transmission
stopped on CH70.
No data from external navigator.
Continued operation possible.
No L/L data
Invalid SOG data
Invalid COG data
Invalid ROT data