    Back UAIS TRANSPONDER FA-100 PRINTED IN JAPAN...
  • Page 2 Printed in Japan All rights reserved. All rights reserved. Pub. No. IME-44170-H5 Pub. No. IME-44170-H5 ( ( AKMU AKMU ) ) FA-100 FA-100 The paper used in this manual is elemental chlorine free. FURUNO Authorized Distributor/Dealer FURUNO Authorized Distributor/Dealer FIRST EDITION : FIRST EDITION : SEP.
  • Page 3 The voltage rating of the equipment appears on the label above the power connector. CAUTION Observe the following compass safe distances to prevent interference to a magnetic compass: Standard Steering compass compass FA-100 1.0 m CB-100 0.6 m GVA-100 0.3 m DB-1 0.3 m PR-240-CE 0.9m Attach securely protection earth to the ship's body.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS SYSTEM CONFIGURATION... iii EQUIPMENT LISTS ... iv 1. MOUNTING ... 1 1.1 Antenna Unit...1 1.1.1 GPS antenna unit ...1 1.1.2 VHF antenna ...3 1.1.3 GPS/VHF combined antenna ...5 1.2 Transponder Unit ...8 1.3 Junction Box...10 1.4 Power Supply (option) ...11 1.5 Pilot Plug (option) ...11 2.
  • Page 5: System Configuration

    1f, 50/60Hz Category of the units GPA-017S Exposed to the weather GSC-001 Exposed to the weather GVA-100 Exposed to the weather FA-100 Protected from the weather CB-100 Protected from the weather DB-1 Protected from the weather PR-240-CE Protected from the weather...
  • Page 6: Equipment Lists

    000-572-184 For FAB-151D 000-113-498 For outside Japan 000-053-911 005-954-420 CD-ROM, USB protect key 005-954-510 Remarks Select one. For DB-1 For FA-100 For CB-100 For GPA-017S For GVA-100 Remarks For GPS or Combined antenna 8D-FB-CV *30M*, CP20-01701 For GPS or Combined antenna...
  • Page 7: Mounting

    000-123-809), coaxial connector(N-P-8DFB; supplied), vulcanizing tape and vinyl tape are required. Fabricate both ends of the cable as shown in the figure on the next page. Conversion Cable Assy. NJ-TP-3DXV-1 Antenna Cable 30 m Fabricate locally. (See next page.) Waterproofing connector : Connector FA-100...
  • Page 8 Dimensions in millimeters. Outer Sheath Armor Inner Sheath Shield Cover with heat-shrink tubing and heat. Clamp Gasket (reddish brown) Trim shield here. Insulator Trim aluminum tape foil here. Clamp Nut Solder through the hole. How to attach connector N-P-8DFB Remove outer sheath and armor by the dimensions shown left.
  • Page 9: Vhf Antenna

    Install the VHF whip antenna referring to the outline drawing at the back of this manual. Separate this antenna from other VHF radiotelephone antennas as shown on the next page to prevent interference to the FA-100.
  • Page 10 Horizontal separation distance Whip antenna for AIS (GPS/VHF combined antenna) Vertical separation distance More than 2.8 m More than 0.5 m When coaxial cable RG-10U/Y (shipyard supply) is used, attach the coaxial plug M-P-7 (dockyard supply) as shown on the next page. Other VHF whip antenna More than 10 m...
  • Page 11: Gps/Vhf Combined Antenna

    How to attach the plug M-P-7 Lay the coaxial cable and attach an M-type plug (if necessary) to the cable as follows. 1. Remove the sheath by 30 mm. 2. Bare 23 mm of the center conductor. Trim braided shield by 5 mm and tin. 3.
  • Page 12 Mounting procedures 1. Dismount the bottom cover, cut the cable-tie inside the unit and take out the coaxial connector attached to the combined box. 2. Loosen four screws to loosen whip antenna fixture and pull out the coaxial connector coming from the combined box through the hole in the whip antenna fixture.
  • Page 13 Installing distributor unit DB-1 The length of the cable between the distributor unit and transponder unit is 1 m so locate the distributor unit within 1 m from the transponder unit. Fix the distributor unit on the bulkhead, facing the cable entrance downward. Remove the lid of the distributor unit and secure the unit with two tapping screws.
  • Page 14: Transponder Unit

    1.2 Transponder Unit The transponder unit can be installed on a desktop or flush mounted in a panel. Install it on the chart table or near the steering place, referring to the outline drawing. When selecting a mounting location for the transponder, keep the following in mind: Keep the transponder out of direct sunlight.
  • Page 15 Flush mounting Optional flush mount kit A or B is required for flush mounting. For mounting dimensions, refer to the outline drawing at the back of this manual. Flush mount kit A: Type OP24-1 Name Cosmetic panel +Tapping screw 1. Cut out a hole in the mounting location, referring to the outline drawing. 2.
  • Page 16: Junction Box

    1.3 Junction Box Mount the junction box where the junction box is protected from rain and water splash. Mounting 1. Open the lid of the junction box and fix the junction box with four tapping screws (5x20). Avoid bundling the 3.3 m cable of the junction box together with any power cable.
  • Page 17: Power Supply (Option)

    1.4 Power Supply (option) The length of the power cable between the power supply and the transponder unit is 3.5 m. Keep this length in mind when selecting a mounting location. A longer cable should not be used – voltage drop will result, affecting performance. When selecting a mounting location for the unit, keep the following in mind: •...
  • Page 18: Wiring

    LAN cable (category 4 or higher) GPS ANT VHF ANT AUX-2 AUX-1 TTYCS-1Q** AD-10 IN EXTRA I/O Transponder unit FA-100 Approx. 3.3 m Junction Box CB-100 0.9 m RG-10/UY Attached to Distributor (approx. 1m) : ground is not required. Gyrocompass...
  • Page 19 **: DPYC-1.5, TTYCS-1Q and TTYCS-4 are Japan Industry Standard cable. Use them or the equivalents. DPYC-1.5 11.7 mm Conductor S = 1.5 mm = 1.56 mm TTYCS-4 (Four twisted pairs) = 18.5 Conductor S = 0.75 mm = 1.11 mm ***: Waterproofing connectors Wrap connector with vulcanizing tape and then vinyl tape.
  • Page 20 Cable Connection at Junction Box Cable fabrication Armor Connection Procedure 1. Insert driver from direction 1 . 2. Tilt slightly toward 2 . 3. Insert cable core to 3 . Sheath Shield 5 to 6 mm Clamp here by cable clamp. Core 5-6 mm...
  • Page 21: Input/Output Signal

    61162-1/2. The protocol is RS422. If there is no HDT signal from a gyrocompass, connect the gyrocompass signal (Synchro or step signal) to the “AD-10 IN” port (D-sub 9 pins) of the transponder unit via the FURUNO A/D Converter AD-100 (See page 16).
  • Page 22: Input/Output Of Ais Signal

    3.2 Input/Output of AIS Signal Three input/output ports are provided for RS-422 protocol, based on the IEC 61162-1/2. Data transmission rate is selectable from 4800 bps and 38.4 kbps. Normally, Radar/ECDIS/PC, etc. are connected to these ports to exchange data with the AIS.
  • Page 23: Input Of Gyrocompass Signal

    If the gyrocompass has no HDT signal, the AD-10 format (FURUNO format) signal can be input via the FURUNO A/D Converter AD-100. Connect the AD-100 to the “AD-10 IN” port (D-sub 9 pin) on the rear panel of the transponder unit.
  • Page 24: Lan Input/Output

    PC), use a LAN cable category 4 or higher with shield (SDT). Connect it to the PC with an RJ-45 connector, and connect to the FA-100 with a D-sub 9 pin connector, to avoid noise leakage. To use a commercial LAN cable, remove one connector and solder a D-sub 9 pin connector, supplied in the installation materials.
  • Page 25: Jumper Setting In The Junction Box

    If multiple equipment are connected to an output port of an external equipment, change to jumper block setting to between the #1 and #2 pins to reduce the load on the FA-100. Then, the input impedance of the RS-422 RX lines in the FA-100 becomes more than 2.4 k ohms.
  • Page 26: Input/Output Sentences

    3.8 Input/Output Sentences 1) SENSOR 1, SENSOR2, and SENSOR3 ports These ports can receive IEC61162-1/2 standard data. The transmission rate of sensor 1, 2, and 3 is selectable from 4800 bps and 38.4 kbps through the menu. Input sentences are as follows: $xxDTM, $xxGBS, $xxGGA, $xxGLL, $xxGNS, $xxHDT $xxOSD, $xxRMC, $xxROT, $xxVBW, $xxVTG Note: The talker of the underlined sentences has priority as...
  • Page 27: Changing Ship's Mains Specifications

    3.9 Changing Ship’s Mains Specifications The power supply PR-240-CE is shipped ready for connection to a 200-230 VAC ship’s mains. If the ship’s mains is 100 VAC – 115 VAC, change the tap connection and terminal board connection as below. Attach label supplied as accessories to the punch mark in the front panel according to the ship’s mains.
  • Page 28: Setting And Adjustment

    3. After the following window appears, enter the password. Note that the password is known by only the FURUNO dealer. 4. Press the [ENT] key to display the SET MMSI & IMO# window. Asterisk marks current selection.
  • Page 29 alphabet and numerical character, press the [SFT] key. To enter an alphabet, press corresponding key several times until desired letter is displayed. For example, if you press the [2] key continuously, the character A, B and C appear cyclically. If you want to enter the same letter or an other letter with the same key (for example, AA or AC), press the [6] key while pressing the [SFT] key, to send the cursor to the next position.
  • Page 30: Setting Gps Antenna Position And Ship's Type

    4.2 Setting GPS Antenna Position and Ship’s Type 1. In the INIT SETTING sub-menu, press the [6] key to open the SET ANTENNA POS window. 2. With 1 selected, press the [ENT] key. The 1 is for entering internal GPS antenna position and 2 is for external GPS which is connected to the AIS.
  • Page 31 Confirm type of ship with ship’s captain before setting it. 8. Press the [2], [4], [6] or [8] key as appropriate to select your ship’s type, referring to the list on below. 10 FUTURE USE ALL SHIPS OF THIS TYPE 11 FUTURE USE CARRYING DG, HS, OR MP(A) 12 FUTURE USE CARRYING DG, HS, OR MP(B) 13 FUTURE USE CARRYING DG, HS, OR MP(C)
  • Page 32: System Settings

    11. With YES selected, press the [ENT] key to save the data. 4.3 System Settings 1. Press the [MENU] key to open the main menu. 2. Press the [6] key to open the SYSTEM SETTINGS sub-menu. 3. Press the [1] key to display the SET I/O PORT sub-menu. 4.
  • Page 33 PC I/O, SNSR 1, SNSR 2, SNSR 3, LR, BCON (beacon receiver), EXTRA1 and EXTRA2, by pressing the [SFT] key. To select each item, press the [NEXT] key. To go backward, press the [NEXT] key while pressing the [SFT] key. 6.
  • Page 34 17. Press the [NEXT] key to select EX1, LR, PC or LAN. 18. Press the [SFT] key to select ENBL (enable) or DSBL (disable) as appropriate. This setting is for communication between FA-100 and each external equipment. “DSBL” disables communication with selected item.
  • Page 35 21. If the FA-100 is connected to a network, enter IP address, sub net mask and port number with the numeric keys and the [NEXT] key. 22. Press the [ENT] key and then the [MENU] key to return to the SYSTEM SETTINGS sub-menu.
  • Page 36 This page is intentionally left blank.
  • Page 37: Packing List

    PACKING LIST PACKING LIST PACKING LIST PACKING LIST FA-100-J/E,FA-100-J/E-HK FA-100-J/E,FA-100-J/E-HK FA-100-J/E,FA-100-J/E-HK FA-100-J/E,FA-100-J/E-HK N A M E ユニット ユニット ユニット ユニット UNIT UNIT UNIT UNIT トランスポンダ部 TRANSPONDER UNIT 工事材料 工事材料 工事材料 工事材料 INSTALLATION MATERIALS INSTALLATION MATERIALS INSTALLATION MATERIALS INSTALLATION MATERIALS コネクタフード(XM2) HOUSING CASE ケーブル組品MJ CABLE ASSY.
  • Page 38 PACKING LIST PACKING LIST PACKING LIST PACKING LIST CB-100-A、CB-100-A-HK CB-100-A、CB-100-A-HK CB-100-A、CB-100-A-HK CB-100-A、CB-100-A-HK N A M E ユニット ユニット ユニット ユニット UNIT UNIT UNIT UNIT 接続箱 JUNCTION BOX UNIT 工事材料 工事材料 工事材料 工事材料 INSTALLATION MATERIALS INSTALLATION MATERIALS INSTALLATION MATERIALS INSTALLATION MATERIALS +トラスタッピンネジ +TAPPING SCREW 1.コ-ド番号末尾の[**]は、選択品の代表型式/コートを表します。 DOUBLE ASTERISK DENOTES COMMONLY USED EQUIPMENT.
  • Page 39 PACKING LIST GVA-100 N A M E ユニット UNIT 複合空中線部 GPS/VHF COMBINED ANTENNA 工事材料 INSTALLATION MATERIALS コネクタ(N) CONNECTOR コンベックス PLASTIC BAND アンテナ取付金具 ANTENNA FIXING BRACKET ミガキ平座金 FLAT WASHER 六角ナット 1種 HEX.NUT (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) DESCRIPTION/CODE № O U T L I N E GVA-100 000-053-810 N-P-8DFB...
  • Page 40 マスト取付金具 工事材料表 工事材料表 工事材料表 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME パイプ PIPE 取付補助金具 INSTALLING SPACER パーカークランプ HOSE CLAMP (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) CODE NO.
  • Page 41 PACKING LIST PACKING LIST PACKING LIST PACKING LIST PR-240-CE PR-240-CE PR-240-CE PR-240-CE N A M E ユニット ユニット ユニット ユニット UNIT UNIT UNIT UNIT AC-DC電源 POWER SUPPLY UNIT 工事材料 工事材料 工事材料 工事材料 INSTALLATION MATERIALS INSTALLATION MATERIALS INSTALLATION MATERIALS INSTALLATION MATERIALS PR-240-CE電源変更手順書 POWER MODIFICATION PROCEDURES デンゲンハリマーク...
  • Page 42 GP-80,GP-90,SC-55,GP-3500/F       工事材料表 工事材料表 工事材料表 工事材料表 GP-1850,GP-1650,FA-100,GP-1640/F     SC-60/120,GD/GP-280/680/380 INSTALLATION MATERIALS 番 号 名  称 NAME アンテナケーブル組品 ANTENNA CABLE ASSY. ケーブル組品 CABLE ASSY. (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)...
  • Page 43 工事材料表 工事材料表 工事材料表 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME 変換ケーブル組品 CONVERT CABLE ASSY. ビニールテープ VINYL TAPE コネクタ(N) CONNECTOR 絶縁テープ SELF-BONDING TAPE (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)...
  • Page 44 マスト取付金具 工事材料表 工事材料表 工事材料表 工事材料表 INSTALLATION MATERIALS 番 号 名  称 NAME パイプ PIPE 取付補助金具 INSTALLING SPACER パーカークランプ HOSE CLAMP (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) CODE NO.
  • Page 46 D - 2...
  • Page 47 D - 3...
  • Page 48 Sep.29'05...
  • Page 49 D-4a May 20 '03...
  • Page 50 Feb.22'05...
  • Page 51 D - 6...
  • Page 52 D - 7...
  • Page 54 Feb.02'05...
  • Page 55 D-10 Nov.28'03...
  • Page 56 D-11...
  • Page 57 D-12...
  • Page 58: Interconnection Diagram

    *7: MAX. CABLE LENGTH IS 0.5m FOR 12 VDC SPECIFICATIONS. *8: SUPPLIED BY AMP INC. CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5 トランスポンダ部 XM2A-3710 24S0058,3.3m TD3-A アオ/アカ1 SNSR3 TRANSPONDER UNIT TD3-B アオ/クロ1 IEC61162-1/2 RD3-A モモ/アカ1 FA-100 RD3-B モモ/クロ1 SNSR2 TD2-A ミドリ/アカ1 TD2-B ミドリ/クロ1 IEC61162-1/2 RD2-A ダイ/アカ1 RD2-B ダイ/クロ1 TD1-A ハイ/アカ1 SNSR1 TD1-B ハイ/クロ1...