This equipment may record the following events in the event log while the OS is running,
Table 4-3 Error / Warning Event Log (While Windows® 10 and Windows Server® 2016 are
DistributedCOM
CD-ROM
atapi
・Source: DistributedCOM, Event ID: 10016 is no problem as long as the content of the
event log corresponds to the following.
< Contents of event log >
The application-specific permission settings do not grant Local Activation permission
for the COM Server application with CLSID {*****} and APPID {*****}
to the user NT AUTHORITY\SYSTEM ID (S-1-5-18) from address LocalHost
(Using LRPC) running in the application container Unavailable SID (Unavailable).
This security permission can be modified using the Component Services administrative
tool.
Please confirm that CLSID and APPID recorded in event log are as follows.
CLSID
APPID
CLSID
APPID
・Source:CD-ROM, Event ID:51 event may be recorded in the event log. As long as you can
access the DVD drive, there is no problem.
・Source
Event ID: 11 event may be recorded even if errors occurred in reading from
:atapi,
the drive and the error recovery was successful after reading normally from the other
drive.
If the error is recovered, an error log occurs once. If it happens multiple times
consecutively within 1 to 2 minutes, there is a possibility that the error recovery has failed.
running) (2/2)
Source
D63B10C5-BB46-4990-A94F-E40B9D520160
9CA88EE3-ACB7-47C8-AFC4-AB702511C276
260EB9DE-5CBE-4BFF-A99A-3710AF55BF1E
260EB9DE-5CBE-4BFF-A99A-3710AF55BF1E
4. PRECAUTIONS WHILE THE OS IS RUNNING
Event ID
10016
51
11
4-3
Type
Error
Error
Error

Advertisement