INSTALLATION CHECK OFF LIST

The following Check-Off Lists must be completed prior to final operation of the Fireplace.
Co-axial vent rigid pipe, wall vent cap or roof vent cap must be installed by a Mendota
approved person in accordance with instructions. All joints must be secured, "twist-
q
locked" and leak-proof. 1000ºF sealant must be used on the inner pipe joints of all Du-
raVent pipe sections.
Horizontal or vertical vent cap must be installed "right-side-up" and tightly sealed to struc-
q
ture per instructions. Vent Caps must be Mendota approved.
Proper exterior and interior clearances for vent systems and locations for wall vent
q
cap/roof vent cap must be maintained.
Carefully check for correct gas pressure, proper size gas lines and for gas leaks.
q
115 V electrical service and gas supply must be installed in accordance with instructions
q
and local and national codes.

LIGHTING CHECK OFF LIST

q
All items on "Installation Check Off List" (see above) must be completed.
Check for gas leaks and gas pressures prior to installing facing materials.
q
Install fresh batteries in remote transmitter. Follow "Initializing the System for the first
q
time" instructions to synchronize the remote control and the receiver.
Check air shutter opening - 0" to 1/8" Nat. gas or 3/8"" to 1/2" LP gas.
q
Carefully follow all Lighting and Log Installation Instructions.
q
Make certain that burner lights immediately. DO NOT proceed with operation unless
q
burner cycles "on/off" without delays.
Make certain that the flame is "stable" and does not "lift" off burner. If flame lifts off
burner, turn unit off and check that all vent pipes are "twist locked" and leak proof, the
vent cap is "right side up" and that 1000º Sealant has been used on the inner pipe joints
q
of all DuraVent pipe sections. DO NOT proceed with operation if flame is "lifting off"
burner.
Note: Do not separate telescoping sections. They must be used as complete assem-
blies.
q
Make certain glass door is in proper closed position and "centered" in firebox opening.
85-03-00955