INSTALLATION CHECK OFF LIST

Co-axial vent rigid pipe, wall vent cap or roof vent cap must be installed by a Mendota
approved person in accordance with instructions. All joints must be secured, "twist-
locked" and leak-proof. 1000ºF sealant must be used on the inner pipe joints of all
DuraVent pipe sections.
Horizontal or vertical vent cap must be installed "right-side-up" and tightly sealed to
structure per instructions. Vent Caps must be Mendota approved.
Proper exterior and interior clearances for vent systems and locations for wall vent
cap/roof vent cap must be maintained.
Carefully check for correct gas pressure, proper size gas lines and for gas leaks.
115 V electrical service and gas supply must be installed in accordance with instructions
and local and national codes.

LIGHTING CHECK OFF LIST

All items on "Installation Check Off List" (see above) must be completed.
Check for gas leaks and gas pressures prior to installing facing materials.
Install fresh batteries in remote transmitter. Follow "Initializing the System for the first
time" instructions to synchronize the remote control and the ignition module.
Check air shutter opening - 0" to 1/8" Nat. gas or 1/4" to 1/2" LP gas.
Carefully follow all Lighting and Log Installation Instructions.
Make certain that burners light immediately and flame runs promptly around "curve" in
rear burner and lights entire burner. DO NOT proceed with operation unless burner cy-
cles "on/off" without delays.
Make certain that the flame is "stable" and does not "lift" off burner. If flame lifts off burn-
er, turn unit off and check that all vent pipes are "twist locked" and leak proof, the vent
cap is "right side up" and that 1000º Sealant has been used on the inner pipe joints of all
DuraVent pipe sections. DO NOT proceed with operation if flame is "lifting off" burner.
Note: Do not separate telescoping sections. They must be used as complete as-
semblies.