Dmx Set Up - ADJ VIZ870 User Instructions

Hide thumbs Also See for VIZ870:
Table of Contents

Advertisement

Vizi CMY300
Special Note: Line Termination. When longer runs of cable are used, you may need to use a terminator
on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the
female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator
(ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
1
DMX512 IN
3
3-PIN XLR
2
5-Pin XLR DMX Connectors. Some manufactures use 5-pin DMX-512 data cables for DATA transmis-
sion in place of 3-pin. 5-pin DMX fixtures may be implemented in a 3-pin DMX line. When inserting
standard 5-pin data cables in to a 3-pin line a cable adaptor must be used, these adaptors are readily
available at most electric stores. The chart below details a proper cable conversion.
Conductor
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
Not Used
Not Used
ADJ Products, LLC - www.adj.com - Vizi CMY300 User Manual Page 10
POWER
Termination reduces signal errors and
avoids signal transmission problems
1
and interference. It is always advisable
3
to connect a DMX terminal, (Resistance
2
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
3-Pin XLR to 5-Pin XLR Conversion
3-Pin XLR Female (Out)
Pin 1
Pin 2
Pin 3
POWER

DMX Set Up

Figure 4
5-Pin XLR Male (In)
Pin 1
Pin 2
Pin 3
Do Not Use
Do Not Use

Advertisement