  • Page 1 User Instructions...
  • Page 2 ©2018 ADJ Products, LLC all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted.
  • Page 3: Table Of Contents

    SPECIFICATIONS ..................................38 ROHS - A great Contribution to the Conservation of Environment ..................39 WEEE – Waste of Electrical and Electronic Equipment ......................39 NOTES ....................................40 A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 3...
  • Page 4: Introduction

    INOZIONE INTRODUCTION Unpacking: Thank you for purchasing the Vizi CMY300 by ADJ Products, LLC. Every Vizi CMY300 has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your fixture for any damage and be sure all accessories necessary to operate the unit has arrived intact.
  • Page 5: Safety Precautions

    C. The fixture has been exposed to rain or water. D. The fixture does not appear to operate normally or exhibits a marked change in performance. E. The fixture has fallen and/or subjected to extreme handling. A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 5...
  • Page 6 INDIVIDUALS SUFFERING FROM A RANGE OF EYE CONDITIONS, SUNLIGHT EXPOSURE DISORDERS, OR INDIVIDUALS USING PHOTOSENSITIVE MEDICATION, MAY RECEIVE DISCOMFORT IF EXPOSED TO THE ULTRAVIOLET (UV) LIGHT EMITTED FROM THIS FIXTURE. A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 6...
  • Page 7: Mounting

    These installation should be checked by a skilled person once a year. The Vizi CMY300 is fully operational in three different mounting positions, hanging upside-down from a ceiling, sideways on trussing, or set on a flat level surface. Be sure this fixture is kept at least 12m (40ft) away from any flammable materials (decoration etc.).
  • Page 8 Screw one clamp each via a M12 screw and nut into the Omega holders. Insert the quick-lock fasteners of the Omega holder’s into the respective holes on the bottom of the Vizi CMY300. Tighten the quick-lock fasteners fully clockwise. Install the second Omega holder. Pull the safety-cable through the openings located on the base plate and over the trussing system or a safe fixation spot.
  • Page 9: Dmx Set Up

    DMX SET UP Power Supply: The ADJ Vizi CMY300 contains an automatic voltage switch, which will auto sense the voltage when it is plugged into the power source. With this switch there is no need to worry about the correct power voltage, this unit can be plugged in anywhere.
  • Page 10 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
  • Page 11: Dmx Addressing

    In the case of the Vizi CMY300, when in 24 Channel you should set the starting DMX address of the first unit to 1, the second unit to 25 (24 + 1), the third unit to 49 (24 + 24 + 1), and so on. (See chart below for more details.)
  • Page 12: Control Panel And Connections

    6. DMX input/output: For DMX 512 operation, use 3/5 pin XLR plug cable to link the units together. 7. Fuse (T10A): Protect the unit from damage of over current. 8. Power Cable: To connect to the main power supply or next fixture. A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 12...
  • Page 13: Channel Mode (Basic Setting)

    0 - 127 GOBO INDEXING 0 - 360 128 - 190 CLOCKWISE ROTATION FAST - SLOW 191 - 192 STOP 193 - 255 COUNTER-CLOCKWISE ROTATION SLOW - FAST A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 13...
  • Page 14 160 - 191 SHUTTER OPEN 192 - 223 RANDOM STROBE EFFECT SLOW - FAST 224 - 255 SHUTTER OPEN MASTER DIMMER 0 - 255 0% - 100% A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 14...
  • Page 15 DIMMER MODES 0 - 20 STANDARD 21 - 40 STAGE 41 - 60 61 - 80 ARCHITECTURAL 81 - 100 THEATER 101 - 255 DEFAULT TO UNIT SETTING A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 15...
  • Page 16 FOCUS COMPENSATE FAR 170 - 199 NOTHING 200 - 209 RESET ALL 210 - 219 RESET EFFECT 220 - 229 RESET PAN/TILT MOTORS 230 - 255 NOTHING A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 16...
  • Page 17: Channel Mode (Standard Setting)

    0 - 127 GOBO INDEXING 0 - 360 128 - 190 CLOCKWISE ROTATION FAST - SLOW 191 - 192 STOP 193 - 255 COUNTER-CLOCKWISE ROTATION SLOW - FAST A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 17...
  • Page 18 160 - 191 SHUTTER OPEN 192 - 223 RANDOM STROBE EFFECT SLOW - FAST 224 - 255 SHUTTER OPEN MASTER DIMMER 0 - 255 0% - 100% A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 18...
  • Page 19 DIMMER MODES 0 - 20 STANDARD 21 - 40 STAGE 41 - 60 61 - 80 ARCHITECTURAL 81 - 100 THEATER 101 - 255 DEFAULT TO UNIT SETTING A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 19...
  • Page 20 FOCUS COMPENSATE FAR 170 - 199 NOTHING 200 - 209 RESET ALL 210 - 219 RESET EFFECT 220 - 229 RESET PAN/TILT MOTORS 230 - 255 NOTHING A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 20...
  • Page 21: Channel Mode (Extended Setting)

    118 - 127 ROTATING GOBO 7 SHAKE 128 - 190 CLOCKWISE SCROLL FAST - SLOW 191 - 192 STOP 193 - 255 COUNTER-CLOCKWISE SCROLL SLOW - FAST A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 21...
  • Page 22 NO ROTATION 193 - 255 COUNTER-CLOCKWISE ROTATION SLOW - FAST 0 - 255 PRISM 2 FINE INDEXING FOCUS 0 - 255 CONTINUOUS ADJUSTMENT FROM NEAR - FAR A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 22...
  • Page 23 FINE IRIS FROST 0 - 255 0% - 100% CMY SPEED & COLOR MACRO SPEED 0 - 255 FAST - SLOW PAN/TILT MOVEMENT SPEED FAST – SLOW A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 23...
  • Page 24 FOCUS COMPENSATE FAR 170 - 199 NOTHING 200 - 209 RESET ALL 210 - 219 RESET EFFECT 220 - 229 RESET PAN/TILT MOTORS 230 - 255 NOTHING A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 24...
  • Page 25 FOCUS COMPENSATE FAR 170 - 199 NOTHING 200 - 209 RESET ALL 210 - 219 RESET EFFECT 220 - 229 RESET PAN/TILT MOTORS 230 - 255 NOTHING A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 25...
  • Page 26: System Menu

    SYSTEM MENU A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 26...
  • Page 27: Operating Instructions

    3. Either “On” or “Off” will displayed. To activate Wireless DMX press the UP or DOWN so that “On” is highlighted and press ENTER. 4. Press the MENU button to exit and return to the main menu. A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 27...
  • Page 28 3. Use the UP or DOWN buttons to scroll through the different dimmer curves. 4. Press ENTER to confirm your selection or press the MENU button to return to the main menu. A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 28...
  • Page 29 2. Use the UP or DOWN buttons to switch between “Auto Test” or “Manual Test”. 3. Press ENTER to confirm your selection or press the MENU button to return to the main menu. A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 29...
  • Page 30 3. Press the MENU button to return to the main menu. USB Upgrade File - This submenu is used for any future software updates. Check www.adj.com and this units webpage for any software updates. Download the software update to a flash stick and plug the flash stick into the Flash Drive slot located on the front of the unit.Contact ADJ customer service for help when updating...
  • Page 31: Wdmx (Wifly) Set Up

    2. After you have set the WiFly address, follow the DMX instructions on page 27 to select your desired DMX Channel mode and set your DMX address. 3. Apply power to the ADJ WiFly Transceiver. The fixture must be set up first before you apply power to WiFly Transceiver.
  • Page 32 ENTER. 2. Use the UP and DOWN buttons to make your adjustments, and then press ENTER to confirm. Press the MENU button for one second to exit. A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 32...
  • Page 33 ENTER. 2. Use the UP and DOWN buttons to make your adjustments, and then press ENTER to confirm. Press the MENU button for one second to exit. A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 33...
  • Page 34: Error Codes

    (8)Gobo1 Reset Error (9)RGobo1 Reset Error (10)Gobo2 Reset Error (11)Prism1 Reset Error (12)RPrsim1 Reset Error (13)Prism2 Reset Error (14)RPrsim2 Reset Error (15)Focus Reset Error (16)Zoom Reset Error A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 34...
  • Page 35: Gobo Specifications

    TEMPERATURE SILICONE SEALANT.GOBO 4 IS SECURED WITH A HIGH TEMPERATURE SILICONE SEALANT ONLY, NO RETAINER SPRING. NO METAL BEZELS ARE USED TO SECURE ANY OF THE FACTORY GOBOS. A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 35...
  • Page 36: Gobos

    6. Insert the gobo frame back into the unit, positioning it in same way as the other gobo frames. 7. Reassemble the unit. A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 36...
  • Page 37: Dimmer Curve Chart

    Rise Time (ms) Down Time (ms) Standard (default) Stage 1100 1540 1660 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 DIMENSIONAL DRAWING A.D.J. Supply Europe B.V. – www.adj.eu – Vizi CMY300 Instruction Manual Page 37...
  • Page 38: Multiple Unit Power Linking

    The maximum that can be connected is 3 fixtures @ 120V and 7 fixtures @ 230V. After the maximum connected fixtures you will need to use a new power outlet. NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES TO THE VIZI CMY300 AS THE POWER CONSUMPTION OF OTHER LIGHTING FIXTURES WILL VARY! FUSE REPLACEMENT Unplug the unit from any power source it may be connected to.