Stp268 Screw Terminal Assignments - Data Translation DT3010 Series Getting Started Manual

Table of Contents

Advertisement

STP268 Screw Terminal Assignments

Screw terminals on the STP268 screw terminal panel are available for
low-current signal conditioning applications. The supply on the
DT3010-268 board is current-limited through a 10 Ω resistor and is
specified for a maximum load current of ±3 mA.
The +5.0 V reference on the STP268 screw terminal panel is also
current-limited through a 10 Ω resistor and is provided for
applications that require a reference less than 1 mA.
The +5 V output signal on the STP268 screw terminal panel is
current-limited through a series 10 Ω resistor and supports loads up
to 100 mA. Note that you must take the drop (current [I] multiplied
by resistance [R]) across the series 10 Ω resistor (1 V at 100 mA) into
consideration.
Note:
If you are connecting a high-speed clock to the STP268, it is
recommended that you connect the return to the adjacent ground
screw terminal.
Table 4
lists the screw terminal assignments on the STP268 screw
terminal panel for connector J1 of the DT3010-268;
screw terminal assignments on the STP268 screw terminal panel for
connector J2 of the DT3010-268.
Wiring Signals
Table 5
lists the
5
5
5
5
5
5
5