Performing A Pulse Output Operation - Data Translation DT3010 Series Getting Started Manual

Table of Contents

Advertisement

Chapter 6

Performing a Pulse Output Operation

116
To verify that the board can perform a pulse output operation,
perform the following steps:
1.
Connect a scope to counter/timer 0 on the DT3010 Series board.
Refer to
page 95
pulse output) to counter/timer 0.
Note: The Quick Data Acq application works only with
counter/timer 0.
2.
Click the Control menu.
3.
Click Pulse Generator.
Select the appropriate DT3010 Series board from the Board list
4.
box.
5.
Select either Continuous to output a continuous pulse stream or
One Shot to output one pulse.
6.
Select either Low-to-high to output a rising-edge pulse (the high
portion of the total pulse output period is the active portion of
the signal) or High-to-low to output a falling-edge pulse (the low
portion of the total pulse output period is the active portion of
the signal).
7.
Enter a percentage or use the slider to select a percentage for the
pulse width. The pulse width determines the duty cycle of the
pulse.
Click Start to generate the pulse(s).
8.
The results are displayed both in text and graphical form.
9.
Click Stop to stop a continuous pulse output operation. One-shot
pulse output operations stop automatically.
for an example of how to connect a scope (a