Important settings

7.7.1 Temperature setpoint setting

The setpoint is the temperature, which the thermostat should reach and maintain constant.
Master (main level)
or
Wait 4 seconds or
YACE0100 / October 4, 2018
SEt
SEt
 Press key until
 Press, display flashes.
 Enter the setpoint with the two keys ( Section 7.4.1 General key
functions and pilot lamps).
 Display flashes 4 seconds  new value is automatically accepted,
or
value is accepted immediately with Enter key.
 For safety reasons the setpoint can only be set up to 2 °C above
upper limit of the operating temperature range for the relevant
device type.
 In the following cases, the manual setpoint entry is blocked:
Setpoint is taken from the analog module, from the programmer in
the Command remote control or via the serial interface.
 When the setpoint temperature is to be lowered, it may take up to
one minute before the blue LED
Starting up
(Setpoint) appears.
lights.