Obtaining Information On A Program (Info) - Lauda Proline RP 845 C Operating Instructions Manual

Table of Contents

Advertisement

T °C
27.00
26.00
25.00
24.00
23.00
00:00
Pump
Menu
02:15

7.10.7 Obtaining information on a program (Info)

Command
Status
Edit
Loops
Graph
Info
Pump
Menu
68
00:45
01:30
End
T
set
Segments
Temp.min 20.00°C
Temp.max 40.00°C
Duration
01:00
Seg. free
Actual Seg.
Seg. Remain00:05
Loop actual
End
Prog.1 Standby
Starting up
Proline Edition X cooling thermostats
 The display of the programmed
temperature curve can be quit with
End .
T
fix
Programmer Program1 Info
 Continue with
2
Here, all information is displayed about the
entered program sequence.
 Number of segments.
145
 Minimum temperature in °C.
5
 Maximum temperature in °C.
 Program duration in hh:mm (without the
3
time, which is necessary to process step
changes in temperature).
 Number of free segments.
 Segment, which is at present (currently)
being processed.
 Residual time of the current segment in
hours and minutes.
 Current pass; in the example the third of
all passes is running.
The last three points are only displayed when a
program runs.
 Quit the window with
or
to
Info
.
or End .