Seawater System, Draining

WARNING!
Risk of water entry. Close the seawater cocks before
doing any work on the seawater system.
The seawater system must be drained during cold
weather when there is a risk of freezing to prevent the
system from bursting. An alternative to draining is to
keep the engine room free from frost using an
approved heater fan.
1 Close the seawater cock.
B
2 Remove the drain plugs A, B (only -TA ), one at
a time, and allow the water to run out until all
drain points on the engine have been
dismantled.
IMPORTANT!
Make sure the coolant really runs out. It may be
necessary to clean away deposits inside the
drain cocks.
3 Drain the water from the reverse gear oil cooler
by opening tap kranen (1).
4 Drain any extra equipment such as the seawater
filter.
5 Connect all hoses, close all drain taps and plugs
before you leave the boat.
47713336 03-2021 © AB VOLVO PENTA