Kemppi MasterMig 353 Operating Manual page 43

Table of Contents

Advertisement

Remote min.
Remote max.
Cable calibration
(MIG only)
Water cooler
Cycle timer
- Time
WF end step
Subfeeder
Arc verification
Weld data
Safe wire inch
(MIG only)
Gas guard (MasterMig 355 only)
Voltage display
PIN code
Device info
© Kemppi
Defined by the active welding program
Defined by the active welding program
Start/Cancel
OFF/Auto/ON
Default = Auto
ON/OFF
Default = OFF
0.0 ... 60.0 s
Default = 2.0 s
OFF/ON
Default = OFF
Subfeeder model / OFF
Default = OFF
1...365
Default = 0 (OFF)
0...10 s, step 1
Default = 5 s
OFF/ON
Default = ON
ON/OFF
Default = OFF
Arc voltage / Terminal voltage
Default = Arc voltage
ON/OFF
43
Operating manual- EN
Minimum and maximum limits for the
remote wire feed speed adjustment.
Calibration information on the previous
calibration is also shown. Refer to "Cal-
ibrating welding cable" on page 33 for
cable calibration.
When ON is selected, the coolant is cir-
culated continually, and when Auto is
selected, the coolant is circulated only
during welding.
A welding function that automatically
produces a weld of a predefined dur-
ation.
Wire feed end step feature prevents the
filler wire from sticking to the contact tip
when the welding ends.
If a compatible subfeeder is connected,
select the subfeeder from the list.
Compatible subfeeders:
SuperSnake GTX 10 m, 15 m, 20 m, 25 m.
Note: For the best possible welding result
when using the pulse and MAX welding
processes with a subfeeder device, we
recommend a maximum subfeeder cable
length of 10 meters (SuperSnake GTX 10
m). This recommendation assumes that
you are using a 5-meter welding gun
cable and a 15-meter earth return cable
together with the subfeeder. In some
cases, it is possible to weld with pulse
and MAX welding processes with a 15-
meter subfeeder device, but a test weld is
advised.
This defines the number of days to the
next device verification.
This defines how long the weld data sum-
mary is shown after each weld.
When ON, and the arc doesn't ignite, the
filler wire is fed 5 cm. When OFF, 5 m of
filler wire is fed.
Gas guard prevents welding without
shielding gas.
This defines which is shown on the con-
trol panel display, arc or terminal voltage.
4-digit PIN code for locking the control
panel after 30 s of inactivity. PIN lock does
not prevent welding, browsing Powerlog
levels or selecting memory channel.
Shows information on the device and its
usage.
MasterMig 353, 355
1921960 / 2217

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents