1.
Memory channel (and filler wire and shielding gas settings, if set)
2.
Active welding process
3.
Applied welding functions*
4.
Applied trigger logic function
5.
Wire feed speed
>> The value range is defined by the active welding program, step 0.1, default = 5.0 m/min
6.
Current and voltage
7.
Dynamics
>> Controls the short circuit behavior of the arc. The lower the value the softer the arc, the higher the value the
rougher the arc. Value range: -9 ... +9, default = 0
>> With MAX process a corresponding MAX parameter adjustment is displayed
8.
Welding voltage
>> With 1-MIG process voltage fine tuning is displayed
>> With MAX process a corresponding MAX parameter adjustment is displayed.
Control knob functions
Left control knob:
•
Manual MIG: Wire feed speed adjustment
•
1-MIG: Wire feed speed adjustment
•
Pulse MIG: Wire feed speed adjustment
•
DPulse MIG: Wire feed speed adjustment and switching between pulse levels with the control knob button
•
TIG/MMA: Welding current adjustment.
Right control knob:
•
Manual MIG: Welding voltage and dynamics adjustment
•
1-MIG: Dynamics adjustment and fine tuning of welding voltage and switching between the adjustments with the
control knob button
•
Pulse MIG: Fine tuning of welding voltage
•
DPulse MIG: Fine tuning of welding voltage
•
MMA: Dynamics adjustment.
* Applied welding functions
Graph
Description
Hot start, Powerlog and crater fill OFF.
Hot start and crater fill ON.
© Kemppi
36
MasterMig 353, 355
Operating manual- EN
1921960 / 2217