Environmental Conditions; Table 3: Environmental Conditions - Kontron COMe Eval Carrier T7 User Manual

Table of Contents

Advertisement

2.2. Environmental Conditions

Table 3: Environmental Conditions

Operating
-0°C to +60°C
Some connectors and supercap has operating temperature only 0°C to +70°C, relative
humidity (non-condensing) 10 % to 93 % at 40°C (acc. to IEC 60068-2-78)
Storage
-30°C to +85°C
relative humidity (non-condensing) 10 % to 93 % at 40°C (acc. to IEC 60068-2-78)
Waste Electrical
Components and materials of the product must not contain lead, mercury, cadmium,
and Electronic
hexavalent, chromium, polybrominated biphenyls (PBB) or polybrominated diphenyl ethers
Equipment (WEEE)
(PBDE). (Directive 2012/19/EU)
RoHS II Compliance
The product will comply with the European Council Directive on the approximation of the
laws of the member states relating to Directive 2011/65/EU or the last status thereof.
Theoretical MTBF
not applicable
EMC according to EN 55032 Class B, IEC/EN 61000-6-3 and EN 55024, IEC/EN 61000-6-2
Compliance
Reach compliant (Regulation (EC) No 1907/2006)
EN 62368-1:2014 - Safety for audio/video and information technology equipment
Component Recognition to UL60950-1 - Information Technology Equipment Including
Electrical Business Equipment
Shock & Vibration according to IEC/EN60068-2-27 (Non-operating shock test – half-
sinusoidal, 11 ms, 15 g) and IEC/EN60068-2-6 (Non-operating vibration – sinusoidal, 10 Hz –
2000 Hz, +/- 0.15 mm, 2 g)
www.kontron.com