Note on Controlling MCU Pins:

• Some MCU pins are controlled by the emulator.
(1) RESET* input
(2) NMI* input

Notes on the Target System (power supply, order of powering on):

• When the target system is connected, be sure to set the JP1 of the emulator to "EXT".
• This emulator cannot supply the power to the target system. Therefore design your system so that
the target system is powered separately.
• This emulator consumes max. 500 mA of electric current from the target system.
• The voltage of the target system should be within the range of 4.5 to 5.5 V.
• Before powering on your emulator system, check that the host machine, the emulator, the converter
board and target system are all connected correctly. Next, turn on the power to each equipment
following the procedure below.
(1) Turn ON/OFF the target system and the emulator as simultaneously as possible.
(2) When the emulator debugger starts up, check the target status LEDs on the emulator to see if
IMPORTANT
The RESET* input from the target system is accepted only while a user program is being
executed (only while the RUN status LED of the emulator is lit).
The NMI* input from the target system is accepted only while a user program is being
executed (only while the RUN status LED of the emulator is lit).
this product is ready to operate.
Is the power supplied?:
Is the clock supplied?:
1
*
When the target system is not connected, the target status LED (POWER) is not lit.
Check that target status LED (POWER) is ON.*
Check that target status LED (CLOCK) is ON.
( 14 / 52 )